Stability of Trace-level VOLatile Organic Compounds Stored in Canisters and Tedlar Bags
نویسندگان
چکیده
منابع مشابه
synthesis of 3-aryl-2h-benzo[b]-1,4-oxazines in [omim]bf4 and reduction of organic compounds in methylimidazolium formate
در این پروژه ترکیبات 3-آریل-2h-بنزو[b]-4،1-اکسازین ها از مواد اولیه تجاری مشتقات دو آمینو فنول و ?-هالو کتون های آروماتیک در مایع یونی 1-اکتیل-3-متیل ایمیدازولیوم تترا فلورو بورات([omim]bf4) سنتز شده است. این واکنش توسط باز پتاسیم کربنات محلول از طریق o-آلکیلاسیون و سپس یک واکنش آمیداسیون درون مولکولی خود بخود در مدت زمان کوتاه انجام می شود. ترکیبات 4،1-بنزوکسازین به این روش با بهره خوب تا آلی ...
15 صفحه اولSome Insights into Analytical Bias Involved in the Application of Grab Sampling for Volatile Organic Compounds: A Case Study against Used Tedlar Bags
In this study, we have examined the patterns of VOCs released from used Tedlar bags that were once used for the collection under strong source activities. In this way, we attempted to account for the possible bias associated with the repetitive use of Tedlar bags. To this end, we selected the bags that were never heated. All of these target bags were used in ambient temperature (typically at or...
متن کاملImpact of Storage Conditions on the Stability of Volatile Sulfur Compounds in Sampling Bags.
Odorous emissions from agricultural and waste management operations can cause annoyance to local populations. Volatile sulfur compounds (VSCs) are dominant odorants that are often lost during collection using sample bags. The degree of VSC losses depends on factors such as storage time, bag materials, temperature, sample relative humidity (RH), light exposure, and the presence of volatile organ...
متن کاملCatalytic Oxidation of Volatile Organic Compounds and Malodorous Organic Compounds
This thesis describes efforts made on the development of an existing catalytic incinerator. The development work, called process characterization, consists of four general parts. These are the development of measurement methodology, the studying of construction materials, the selection of suitable catalysts and the testing of the effects of process operation conditions. The two application area...
متن کاملVolatile Organic Compounds in Uremia
BACKGROUND Although "uremic fetor" has long been felt to be diagnostic of renal failure, the compounds exhaled in uremia remain largely unknown so far. The present work investigates whether breath analysis by ion mobility spectrometry can be used for the identification of volatile organic compounds retained in uremia. METHODS Breath analysis was performed in 28 adults with an eGFR ≥ 60 ml/min...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Aerosol and Air Quality Research
سال: 2003
ISSN: 1680-8584,2071-1409
DOI: 10.4209/aaqr.2003.06.0003