Stability of adenosine 6 μg/mL in 0.9% sodium chloride solution
نویسندگان
چکیده
منابع مشابه
Stability of colistimethate sodium in aqueous solution.
Colistimethate sodium, increasingly used to treat multidrug-resistant Gram-negative infections, spontaneously hydrolyzes to form colistin A (polymyxin E1) and B (polymyxin E2/B) when mixed with water. High levels of these active breakdown products at the time of administration have been associated with nephrotoxicity and even death. In this study, reconstituted colistimethate sodium was shown t...
متن کاملStability of diluted adenosine solutions in polyvinyl chloride infusion bags.
PURPOSE The stability of diluted adenosine solutions in polyvinyl chloride infusion bags was studied. METHODS Adenosine 50-, 100-, and 220-μg/mL solutions were prepared in 50-mL polyvinyl chloride (PVC) infusion bags containing 0.9% sodium chloride injection or 5% dextrose injection and stored at room temperature (23-25 °C) or under refrigeration (2-8 °C). Each sample of every combination of ...
متن کاملCOMPARISON BETWEEN THE EFFECTS OF 5 PERCENT HYPERTONIC SODIUM CHLORIDE SOLUTION AND 0.9 PERCENT SODIUM CHLORIDE SOLUTION ON LEFT VENTRICUL AR CONTRACTION
Hypertonic saline solution can absorb part of the intracellular fluid volume into the extracellular space. The effects of this solution on the cardiovascular system are increased coronary flow and increased left ventricular contraction, without sympathetic system activation. This study was designed to assess the effects of hypertonic saline solution in open heart surgery and to compare it w...
متن کاملIMPROVED CHROMATOGRAPHIC METHOD FOR DETERMINATION OF SODIUM DICLOFENAC IN INJECTABLE SOLUTION AND PREDICTION OF CHEMICAL STABILITY
Two modified methods for assaying sodium diclofenac were developed by GC and HPLC. Diclofenac was converted into methyl ester derivative by methyl iodide in acetone. The ester was extract and subjected to GLC with flame ionization detector. %5 SE-30/chrom W-HP (80-100 mesh) was used as a column in GC. For reversed phase HPLC, the mobile phase was methanol and water (55-45). The separation was p...
متن کاملResuscitation of severe uncontrolled hemorrhage: 7.5% sodium chloride/6% dextran 70 vs 0.9% sodium chloride.
OBJECTIVES Resuscitation studies of hypertonic saline using controlled and uncontrolled hemorrhage models yield conflicting results with regard to efficacy. These disparate results reflect the use of models and resuscitation regimens that are not comparable between studies. This study evaluated the effects of comparable and clinically relevant resuscitation regimens of 7.5% sodium chloride/6% d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Health-System Pharmacy
سال: 1998
ISSN: 1079-2082,1535-2900
DOI: 10.1093/ajhp/55.11.1161