Stability-indicating RP-HPLC method for estimation of miglitol in bulk and tablets
نویسندگان
چکیده
منابع مشابه
Stability-Indicating RP-HPLC Method for Estimation of Miglitol in Bulk and Tablets
A selective and sensitive, stability-indicating reverse phase high performance liquid chromatography method has been first developed and validated for the estimation of miglitol in bulk and tablet dosages form. Samples were separated on a prepacked, Inertsil amino C(18) column (150×4.6 mm i.d.) using a mobile phase comprised of acetonitrile and monobasic sodium phosphate pH 7.5 (80:20, v/v) del...
متن کاملA New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms
A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...
متن کاملStability-indicating RP-HPLC Method for the Simultaneous Determination of Sitagliptin and Simvastatin in Tablets
A new stability-indicating high-performance liquid chromatographic method for simultaneous analysis of sitagliptin and simvastatin in pharmaceutical dosage form was developed and validated. The mobile phase consisted of methanol and water (70:30, v/v) with 0.2 % of n-heptane sulfonic acid adjusted to pH 3.0 with ortho phosphoric acid was used. Retentions of sitagliptin and simvastatin were 4.3 ...
متن کاملValidation of a Stability-Indicating RP-HPLC Method for Determination of l-Carnitine in Tablets
A rapid and stability-indicating RP-HPLC method was developed for determination of l-carnitine in tablets. The separation was based on a C18 analytical column using a mobile phase which consisted of 0.05 M phosphate buffer (pH = 3): ethanol (99 : 1), including 0.56 mg/mL of sodium 1-heptanesulfonate. Column temperature was set at 50°C and quantitation was achieved by UV detection at 225 nm. In ...
متن کاملA Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets
A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile ph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Pharmaceutical Sciences
سال: 2010
ISSN: 0250-474X
DOI: 10.4103/0250-474x.84594