STABILITY INDICATING RP-HPLC ASSAY METHOD FOR ESTIMATION OF MIDODRINE HYDROCHLORIDE IN BULK AND TABLETS

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability-Indicating RP-HPLC Method for Estimation of Miglitol in Bulk and Tablets

A selective and sensitive, stability-indicating reverse phase high performance liquid chromatography method has been first developed and validated for the estimation of miglitol in bulk and tablet dosages form. Samples were separated on a prepacked, Inertsil amino C(18) column (150×4.6 mm i.d.) using a mobile phase comprised of acetonitrile and monobasic sodium phosphate pH 7.5 (80:20, v/v) del...

متن کامل

A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets

A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile ph...

متن کامل

A Stability-Indicating RP-HPLC Assay Method for 5-Fluorouracil

The present study describes the development of a validated RP-HPLC method for the determination of 5-fluorouracil in presence of its degradation products or other pharmaceutical excipients. Stress studies were performed on 5-fluorouracil and it was found that it degrades sufficiently in alkaline conditions, while negligible degradation was observed in acidic, neutral, oxidative and photolytic c...

متن کامل

Stability-Indicating HPLC Method for Posaconazole Bulk Assay

A stability-indicating liquid chromatographic (LC) method was developed for the determination of posaconazole in bulk. Chromatographic separation was achieved using an isocratic elution in a reversed-phase system, with a mobile phase composed of methanol-water (75:25, v/v), at 1.0 mL min(-1) flow. Samples were exposed to degradation under thermal, oxidative and acid/basic conditions, and no int...

متن کامل

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Pharmacy and Pharmaceutical Sciences

سال: 2016

ISSN: 0975-1491

DOI: 10.22159/ijpps.2016v8i9.13619