Stability-Indicating HPTLC Method for Determination of Nebivolol Hydrochloride and Valsartan
نویسندگان
چکیده
منابع مشابه
Stability Indicating HPTLC Determination of Meloxicam
A simple, selective, precise and stability-indicating high-performance thin layer chromatographic method of analysis of meloxicam both as a bulk drug and in formulation has been developed. The mobile phase selected was ethyl acetate:cyclohexane:glacial acetic acid (6.5:3.5:0.02% v/v/v). The calibration curve of the drug was linear in the range of 100-500 ng. The spectrodensitometric analysis wa...
متن کاملStability-Indicating HPLC Method for Determination of Nalbuphine Hydrochloride
A simple, sensitive, stability-indicating HPLC method was developed and validated for the quantitative determination of nalbuphine hydrochloride in presence of its degradation product.The analysis was carried out on a BDS Hypersil C18 ( 250 X 4.6 X 5μm particle size) using a mobile phase consisting of 5 mM sodium acetate buffer; pH 5.5: acetonitrile (40:60, v/v). The analysis was performed at a...
متن کاملStability-indicating HPTLC determination of ambroxol hydrochloride in bulk drug and pharmaceutical dosage form.
A simple, selective, precise, and stability-indicating high-performance thin-layer chromatographic (HPTLC) method for the analysis of ambroxol hydrochloride both as a bulk drug and in formulations was developed and validated. The method employed HPTLC aluminium plates precoated with silica gel 60F-254 as the stationary phase. The solvent system consisted of methanol-triethylamine (4:6 v/v). The...
متن کاملA Validated Stability Indicating HPTLC Method for Determination of Cephalexin in Bulk and Pharmaceutical Formulation
A simple, specific, precise and stability-indicating high performance thin layer chromatographic method of analysis of Cephalexin, both as a bulk drug and in formulation was developed and validated. The method employed TLC (Thin Layer Chromatography) aluminum plates pre-coated with silica gel 60 F254 as the stationary phase. The solvent system consisted of Ethyl Acetate : Methanol : Ammonia (6:...
متن کاملSimultaneous Estimation of Nebivolol Hydrochloride and Valsartan using RP HPLC
In this study, a rapid, precise, accurate, specific and sensitive ion-paired reverse phase liquid chromatographic method has been developed for the simultaneous estimation of nebivolol hydrochloride and valsartan in their capsule formulation. The chromatographic method was standardized using a HIQ sil C(18) column (250x4.6 mm i.d., 5 mum particle size) with UV detection at 289 nm and flow rate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Pharmaceutical Research
سال: 2009
ISSN: 2454-8405,0973-7200
DOI: 10.18579/jpcrkc/2009/8/4/79703