St. Jude Medical valve prosthesis

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

BACKGROUND From October 1977 to October 2002, 4,480 patients (age range, 17 to 94 years; average, 64 +/- 13 years) underwent single valve replacement with the St. Jude Medical heart valve. Of 2,982 aortic (AVR) and 1,498 mitral valve replacements (MVR), concomitant coronary artery bypass grafting was performed on 42% and 33%, respectively. METHODS Cardiac Surgical Associates has maintained an...

متن کامل

Severe haemolytic anaemia after replacement of the mitral valve by a St Jude medical prosthesis.

Severe haemolytic anaemia developed in a 33 year old patient after the mitral valve was replaced with a St Jude medical prosthesis. This was the patient's third thoracotomy. She had already had a mitral commissurotomy and a mitral valve bioprosthesis. The patient had an E+ antibody to red blood cells as well as a paraprosthetic leak. The haemolysis became less severe once the population of E+ r...

متن کامل

Twenty-five year experience with the St. Jude medical mechanical valve prosthesis.

BACKGROUND We evaluated all adult St. Jude mechanical valve recipients at our institution since the initial implant in January 1979 and now present our 25-year experience. METHODS Nine hundred forty-five valve recipients were followed prospectively at 12-month intervals from January 1979 to December 2007. RESULTS Operative mortality was 3% in the aortic valve recipients and 5% in the mitral...

متن کامل

Long-term outcomes after St. Jude Medical mechanical valve implantation.

patient-year), major bleeding events (1.0%/patient-year), and aortic valve reoperation (0.26%/patient-year). They also reported that valve-related death was the most common cause of death (26.8%) and that the rates of freedom from valve-related death were 96.2%, 92.7%, 88.8%, and 86.6% at 5, 10, 15, and 20 years, respectively. These results compare favorably with the findings of previous report...

متن کامل

Isolated mitral valve replacement with St. Jude medical prosthesis: long-term results: a follow-up of 19 years.

BACKGROUND In this retrospective study, approximately 440 patients received mitral valve replacements with the St Jude Medical prosthesis. The last patient was operated on 10 years before the beginning of the follow-up. The extended follow-up was 19 years. METHODS AND RESULTS Four hundred forty patients (sex ratio, 1.32 [men to women]; age, 60+/-11.4 years; age range, 7 to 75 years) were oper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Thoracic and Cardiovascular Surgery

سال: 1981

ISSN: 0022-5223

DOI: 10.1016/s0022-5223(19)39341-9