SRK II formula in the calculation of intraocular lens power.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SRK II formula in the calculation of intraocular lens power.

We studied 400 eyes which underwent cataract extraction with posterior chamber intraocular lens (IOL) implantation to compare the predictive accuracy of various IOL power calculation formulae. The new Sanders-Retzlaff-Kraff (SRK) II formula was more accurate than the original SRK and Binkhorst II formulae. Modification of the A constants used in the SRK II formula to make it 'surgeon specific' ...

متن کامل

Matrix formula for intraocular lens power calculation.

The matrix calculation was applied to Gaussian optics. Matrices were defined for a single diopter, a lens, an association of two centered systems having the same axis when the origins are taken at the vertices of the first and last refracting surfaces. The matrix formula then was used to calculate the power of the emmetropizing lens implant, and its results compared with the ones obtained by fi...

متن کامل

Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation

Purpose To compare the performance of OKULIX ray-tracing software with SRK-T and Hoffer Q formula in intraocular lens (IOL) power calculation in patients presenting with cataract. Methods In this prospective study, 104 eyes of 104 patients with cataract who underwent phacoemulsification and IOL implantation were recruited. Three IOL brands were used and for all eyes, IOL power calculation was...

متن کامل

Comparison of intraocular lens power calculation using the Binkhorst and SRK formulae: a clinical study.

Comparison of results of intraocular lens implants with IOL powers obtained by Binkhorst and SRK Linear Regression formulae was done using various models and brands of intraocular lenses. Of 887 pseudophakic patients. 415 patients received IOL's with their powers calculated for planned emmetropia, by means of theoretic formula devised by R.D. Binkhorst and in the remaining 472 eyes the IOL powe...

متن کامل

Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Ophthalmology

سال: 1989

ISSN: 0007-1161

DOI: 10.1136/bjo.73.10.823