Square-wave polarographic determination of impurities in monosodium glutamate
نویسندگان
چکیده
منابع مشابه
Does Monosodium Glutamate Induce Obesity in Female Mice?
Objective: Female metabolism is highly responding towards diet associated changes. Monosodium glutamate is a popular flavor enhancer, which is widely used to develop umami taste. Young female generation nowadays deals with more issues related to metabolism and fertility. Present study is an effort to monitor the effect of monosodium glutamate oral consumption on female mice health and obesity. ...
متن کاملDevelopment of biosensor based on immobilized L-glutamate oxidase for determination of monosodium glutamate in food.
A monosodium glutamate (MSG) biosensor with immobilized L-glutamate oxidase (L-GLOD) has been developed and studied for analysis of MSG in sauces, soup etc. The immobilized enzymatic membrane was attached with oxygen electrode with a push cap system. The detection limit of the sensor was 1 mg/dl and the standard curve was found to be linear upto 20 mg/dl. Response time of the sensor was 2 min. ...
متن کاملPolarographic determination of malononitrile.
A procedure is proposed for the determination of malononitrile by differential pulse polarography in methanolic 0.1M tetraethylammonium iodide/0.001M tetramethylammonium hydroxide as the supporting electrolyte. In this medium malononitrile is chemically converted into an electroactive species. With close control of timing of the steps in the procedure the error of the method is +/-1.5% in the c...
متن کاملDetermination of clopidogrel using square wave voltammetry
The determination of clopidogrel, an antiplatelet agent, was performed at a gold electrode in pH 3.7 acetate buffer using cyclic voltammetry (CV) and square wave voltammetry (SWV). Each voltammogram was characterized by the well defined peak at approximately 1.0 V. The current of anodic stripping peak exhibited a linear dependence on the clopidogrel concentration in the range from 317.89 to 935...
متن کاملSquare Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Cal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1961
ISSN: 0525-1931