We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with -7.75 -4.25 × 0° and -8.25 -5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the l...
متن کاملPseudophakic ametropia management with toric implantable collamer lens with a central hole (case report)
BACKGROUND To report the clinical outcomes of correcting pseudophakic ametropia using toric implantable collamer lens with a 360 um central hole (TICL V4c). CASE PRESENTATION The right eye of a 22-year-old male patient developed high myopia after unilateral phacoemulsification and intraocular lens (IOL) implantation following traumatic cataract 16 years ago. The manifest refraction was -11.50...
متن کاملVisual outcomes and patient satisfaction after implantable collamer lens and Toric implantable collamer lens correction for moderate to high myopia and myopic astigmatism.
OBJECTIVE To compare preoperative and postoperative visual outcomes, determine patient's satisfaction, and evaluate visual symptoms after implantable collamer lens (ICL) implantation. METHODS One hundred and twelve patients with myopia between -2.75 and -19.50 diopter had ICL or Toric ICL (TICL) implantation. The implantations were carried out at the Cornea and Refractive Unit, Magrabi Eye Ho...
متن کاملStandardized analyses of correction of astigmatism with the visian toric phakic implantable collamer lens.
PURPOSE To demonstrate the methodology described by the American National Standards Institute (ANSI) Standard Subcommittee on Astigmatism Analysis reporting a standardized method of presenting astigmatism data by laser systems that reshape the cornea also applies to toric phakic intraocular lens (IOL) data. METHODS The U.S. Food and Drug Administration trial of the Visian Toric Implantable Co...
متن کاملoutcomes and complications of implantable collamer lens and toric implantable collamer lens for the correction of high myopia with and without astigmatism
purpose: to evaluate the efficacy, safety, predictability and stability of implantable collamer lens (icl) and toric icl for the treatment of high myopia and high myopic astigmatism, one year prospective study. methods: in this prospective nonrandomized clinical trial, 95 eyes of 51 patients that had icl (31 eyes) and toric icl (64 eyes) were participate in eye research center, department of o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BMC Ophthalmology
سال: 2020
ISSN: 1471-2415
DOI: 10.1186/s12886-020-01597-5