SPLENIC INCREASED 18F‐FDG UPTAKE IN PET SCAN PERFORMED FOLLOWING TREATMENT WITH PEG‐GCSF LIPEFILGASTRIM
نویسندگان
چکیده
منابع مشابه
[Splenic and bone marrow increased 18F-FDG uptake in a PET scan performed following treatment with G-CSF].
We present the case of an 11 year-old Caucasian girl who presented chest pain of 12 weeks evolution, with no other symptoms and a negative physical examination. Lactate dehydrogenase levels were increased to 797 U/l, whereas beta-2-microglobulin (BM2) levels were normal. The thoracic CT showed a bulky mediastinal mass that occupied the pretracheal, paratracheal and right prevascular regions. Th...
متن کاملGiant enostosis of spine with increased uptake on planar and SPECT views of bone scan
An enostosis or bone island is a benign bony lesion that is almost diagnosed based on clinical and radiologic defining characteristics. One of the known diagnostic procedures in the evaluation of enostosis is bone scintigraphy. Generally, we don’t expect to see increased uptake by enostosis in the bone scan. Herein we present a 52-year-old lady who was suffering from chronic low back pain that ...
متن کاملDiffuse increased uptake on bone scan: super scan.
From the Institute of Nuclear Medicine and Department of adiology, Assaf Harofeh Medical Center, Zerifin 70300, Israel affiliated with the Sackler Faculty of Medicine, Tel Aviv niversity, Israel). Address reprint requests to Tifha Horne, MD, Institute of uclear Medicine, Assaf Harofeh Medical Center, Zerifin 0300, Israel. © 2004 Elsevier Inc. All rights reserved. 0001-2998/04/3402-0007$30.00/0 ...
متن کاملstimate bowtie filter shape in PET/CT scan with TLD
Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...
متن کاملEstimate bowtie filter shape in PET/CT scan with TLD
Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Hematological Oncology
سال: 2021
ISSN: 0278-0232,1099-1069
DOI: 10.1002/hon.98_2881