Spiral-Shaped Piezoelectric MEMS Cantilever Array for Fully Implantable Hearing Systems

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Simulation of Piezoelectric MEMS Cantilever

In this paper, a Micro – Electrical Mechanical System (MEMS) energy harvester is developed, using the phenomenon of Piezoelectricity. Zinc Oxide (ZnO) was chosen as the piezoelectric material. A multi – d31 mode cantilever design was used with varying dimensions of cantilever, to form an array. The individual cantilevers can be either connected in series or parallel to achieve different output ...

متن کامل

Optimization of MEMS Based Capacitive Accelerometer for Fully Implantable Hearing Aid Application

INTRODUCTION: According to the 2015 estimates of WHO, 278 million people have disabling hearing impairment. In India, 63 million people suffer from significant auditory loss. The majority of all hearing loss is sensorineural loss which refers to hair cells damage in cochlea, a snail like structure inside the inner ear which connects to the auditory nerve in the brain. The use of conventional he...

متن کامل

Optimization of MEMS Capacitive Accelerometer as Fully Implantable Middle Ear Microphone for Hearing Aid

This work describes the design and optimization of three prototypes of microelectromechanical systems (MEMS) capacitive accelerometer-based middle ear microphone. The microphone is intended for middle ear hearing aids as well as future fully implantable cochlear prosthesis. The analysis is done using COMSOL Multiphysics. The maximum applied acceleration was considered 1g. Human temporal bones a...

متن کامل

Two-Port Piezoelectric Silicon Carbide MEMS Cantilever Resonator

A two-port silicon carbide single-clamped beam (cantilever) microelectromechanical system (MEMS) resonant device actuated piezoelectrically and sensed piezoelectrically has been designed, fabricated and tested. Lead zirconium titanate (PZT) has been used as active material to implement the piezoelectric actuator and sensor. Piezoelectric electrodes have been placed on the top of the single 3C-S...

متن کامل

Optimization of Device Geometry of a Fully Implantable MEMS Hearing Aid Microphone by Genetic Algorithm

The paper presents the performance optimization of a MEMS accelerometer based microphone for the fully implantable hearing application. A genetic algorithm is employed to optimize the device geometry parameters satisfying the design constraints. The analytical model run on MATLAB and the simulation model implemented in COMSOL MULTIPHYSICS 4.2 show good agreement. Optimization with Genetic algor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Micromachines

سال: 2017

ISSN: 2072-666X

DOI: 10.3390/mi8100311