Spinal anaesthesia for Caesarean section after Harrington instrumentation
نویسندگان
چکیده
منابع مشابه
Speechless after general anaesthesia for caesarean section.
'Speechless' patient after general anesthesia may be a real horror for the anaesthetist as well as the patient and his relatives. Whatever the cause "functional or organic" the anaesthetist will be under pressure as his patient is not able to talk. Here we report a 40 years old patient who has no history of medical problems and developed aphemia after general anaesthesia for emergency caesarean...
متن کاملAnaesthesia for caesarean section.
Quality and choice in anaesthesia for caesarean section have significantly improved over the last two decades. During this time, general anaesthesia usage has decreased to the point where, in some centres, it is an occasionally used technique for severe fetal distress. This change in practice may have been responsible for the fall in anaesthetic deaths in pregnant women that has occurred over t...
متن کاملAnaesthesia for caesarean section.
Self Assessment Q1 When considering indications and categorisation of caesarean sections: a) Caesarean section caries an overall higher neonatal mortality compared with normal delivery? b) Recommended population caesarean section rates are less than 5%? c) Breech presentations should routinely be booked for a Category 4 caesarean section? d) A category 1 caesarean section should aim to be deliv...
متن کاملSpinal anaesthesia for Caesarean section: effect of Sprotte needle orientation.
We induced spinal anaesthesia in 100 women presenting for elective Caesarean section with the mother in the right lateral position. Patients were allocated randomly to have the side eye of the 24-gauge Sprotte spinal needle pointing in one of four directions: group A, cephalad; group B, right lateral; group C, left lateral; group D, caudad. Isobaric bupivacaine 0.5% (2.5 ml) was injected over 3...
متن کاملSpinal anaesthesia with lidocaine 2% for caesarean section.
Spinal anaesthesia with 2, 2.5 or 3 ml of glucose-free lidocaine 2% was studied in 50 patients undergoing Caesarean section. Onset time, cephalad spread of analgesia, quality of analgesia, muscle relaxation, the cardiovascular effects and duration of analgesia and motor block were assessed. Reliable anaesthesia was provided with 2.5 and 3 ml while 2 ml of 2% lidocaine was insufficient. Onset ti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Journal of Anaesthesia
سال: 1993
ISSN: 0832-610X,1496-8975
DOI: 10.1007/bf03009704