Spike Detection of Disturbed Power Signal Using VMD
نویسندگان
چکیده
منابع مشابه
Signal detection Using Rational Function Curve Fitting
In this manuscript, we proposed a new scheme in communication signal detection which is respect to the curve shape of received signal and based on the extraction of curve fitting (CF) features. This feature extraction technique is proposed for signal data classification in receiver. The proposed scheme is based on curve fitting and approximation of rational fraction coefficients. For each symbo...
متن کاملP81: Detection of Epileptic Seizures Using EEG Signal Processing
Epilepsy is the most common brain diseases that cause many problems in the daily life of the patient. In most attempts to automatic detection, the attack used an EEG. In this paper, The complete data set consists of five sets recorded from normal and epileptic patients. Each set containing 100 single-channel EEG segments. Here we used first and last sets (A and E). Set A consisted of segments r...
متن کاملEstimation of harmonic interference parameters of surface-NMR signal using an adaptive method and residual signal power
Surface nuclear magnetic resonance (surface-NMR) method is a well-known tool for determining the water-bearing layers and subsurface resistivity structure. Harmonic interference is an inevitable interference in surface-NMR measurements. Accurate estimation of harmonic interference parameters (i.e., fundamental frequency, phase and amplitude) leads to better retrieval of power-line harmonics and...
متن کاملDefect detection using power supply transient signal analysis
Transient Signal Analysis is a digital device testing method that is based on the analysis of voltage transients at multiple test points. The power supply transient signals of an 8-bit multiplier are analyzed using both hardware and simulations experiments. The small signal variations generated at these test points are analyzed in both the time and frequency domain. A simple statistical procedu...
متن کاملDetection of power oscillation and simultaneous faults using Clark transform
Distance relays are widely used to protect transmission lines. Sometimes, in these lines due to the occurrence of the oscillation of the power, the impedance calculated in the distance relay enters into its functional zones and leads to the cutting off of the lines. This issue can cause global power outages. Accordingly, in this paper, a Clark-based method for detecting the oscillation of power...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Procedia Computer Science
سال: 2015
ISSN: 1877-0509
DOI: 10.1016/j.procs.2015.01.021