Spiegelmer-Based Sandwich Assay for Cardiac Troponin I Detection

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical performance of the i-STAT cardiac troponin I assay.

BACKGROUND This study determines the analytical characteristics of the i-STAT cardiac troponin I assay (cTnI; i-STAT, Princeton, NJ), a 10-min POC assay, designed to be performed at the bedside. METHODS Three different hospitals participated in a patient specimen and analytical validation study (n=186) for the i-STAT cTnI assay carried out in real time. A total of 186 whole blood specimens (l...

متن کامل

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...

متن کامل

Highly sensitive cardiac troponin I assay leads to lowered specificity.

I read with great interest the article of Kavsak et al. (1 ) on the utility of a next-generation high-sensitivity Beckman Coulter cardiac troponin I (cTnI) assay with a 20% CV at 2.95 ng/L. This approach demonstrated a higher diagnostic sensitivity (81% vs 62%) for myocardial injury with a changing pattern of cTnI values, compared with the AccuTnI assay cleared by the US Food and Drug Administr...

متن کامل

Biologic variation of a novel cardiac troponin I assay.

Cardiac troponin is the marker of choice for evaluating myocardial injury (1 ). High-sensitivity assays improve analytical detection limits, thereby allowing concentrations to be measured in the majority of healthy individuals. This capability allows an assessment of biologic variation (BV) to determine what constitutes an important change in the cardiac troponin concentration, a critical metri...

متن کامل

Time-resolved fluorescence aptamer-based sandwich assay for thrombin detection.

In the present study, the authors report a novel sensitive method for the detection of thrombin using time-resolved fluorescence sensing platform based on two different thrombin aptamers. The thrombin 15-mer aptamer as a capture probe was covalently attached to the surface of glass slide, and the thrombin 29-mer aptamer was fluorescently labeled as a detection probe. A bifunctional europium com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Molecular Sciences

سال: 2020

ISSN: 1422-0067

DOI: 10.3390/ijms21144963