Spectrophotometric determination of thorium (IV) with Xylenol Orange and Methylthymol Blue

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solid Phase Spectrophotometric Determination Of Cobalt By Xylenol Orange

A simple and sensitive solid phase spectrophotometric method for the determination of cobalt is proposed based on the reaction between cobalt and xylenol orange (XO). The reaction product is fixed on the anionic exchanger resin sephadex QAE A-25 at pH= 5. The optical absorbance of the anionic gel like resin, packed in a 1.00 mm cell is directly measured at 588.0 nm. The linear range of calibrat...

متن کامل

Sulfonephthalein dyes. П.* Protolytic equilibria of methylxylenol blue

Methylxylenol blue or S^'-bis-Z^jiV'-diicarboxymethylJaminomethyl-^-xylenolsulfonephthalein belongs to the group of metallochromic indicators prepared by Körbt and Přibil [1] via condensation of common sulfonephthalein dyes with formaldehyde and iminodiacetic acid. Recently it has been newly prepared by Cherkesov and co-workers [2] and named ^-xylenolphthalexon S. Two indicators from this group...

متن کامل

Simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares

A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...

متن کامل

Spectrophotometric and derivative spectrophotometric determination of aluminium with Hydroxynaphthol Blue.

The reaction of aluminium(III) with Hydroxynaphtol Blue (HNB) in aqueous media at apparent pH 5.5 results in a red complex that is stable for at least 4 hr. Beer's Law is obeyed up to 1.6 microg/ml of aluminium(III) with an apparent molar absorptivity of 1.66 x 10(4) l.mol(-1). cm(-1) at 569 nm. This paper proposes procedures for aluminium(III) determination by ordinary and first-derivative spe...

متن کامل

simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares

a partial least squares (pls) calibration model was developed for the simultaneous spectrophotometricdetermination of pb (ιι), cu (ιι) and ni (ιι) using xylenol orange as a chromogenic reagent. the parameterscontrolling behavior of the system were investigated and optimum conditions were selected. the calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BUNSEKI KAGAKU

سال: 1965

ISSN: 0525-1931

DOI: 10.2116/bunsekikagaku.14.229