Spectral-resolved cone-beam X-ray luminescence computed tomography with principle component analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Collimated superfine x-ray beam based x-ray luminescence computed tomography.

X-ray luminescence computed tomography (XLCT) is a hybrid imaging modality with the potential to achieve a spatial resolution up to several hundred micrometers for targets embedded in turbid media with a depth larger than several millimeters. In this paper, we report a high spatial resolution XLCT imaging system with a collimated superfine x-ray beam in imaging the deeply embedded targets. A co...

متن کامل

X-ray luminescence computed tomography using a focused x-ray beam.

Due to the low x-ray photon utilization efficiency and low measurement sensitivity of the electron multiplying charge coupled device camera setup, the collimator-based narrow beam x-ray luminescence computed tomography (XLCT) usually requires a long measurement time. We, for the first time, report a focused x-ray beam-based XLCT imaging system with measurements by a single optical fiber bundle ...

متن کامل

Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).

A theoretical method is presented that allows identification of optimal x-ray imaging geometry, considering the effects of x-ray source distribution, imaging task, x-ray scatter, and imager detective quantum efficiency (DQE). Each of these factors is incorporated into the ICRU-recommended figure of merit for image quality, the detectability index, which is maximized to determine the optimal sys...

متن کامل

Phase Contrast Imaging with High Resolution Cone Beam X-ray Computed Tomography

X-ray computed tomography (XCT) with cone beam geometry has become a very important method for non-destructive 3D-characterisation and evaluation of materials. Compact XCT systems can reach resolutions down to 1 μm and even below. However, the polychromatic nature of the source, limited photon flux and the consequent long measurement times as well as all kinds of measurement artifacts lead to l...

متن کامل

Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.

A system for cone-beam computed tomography (CBCT) based on a flat-panel imager (FPI) is used to examine the magnitude and effects of x-ray scatter in FPI-CBCT volume reconstructions. The system is being developed for application in image-guided therapies and has previously demonstrated spatial resolution and soft-tissue visibility comparable or superior to a conventional CT scanner under condit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Biomedical Optics Express

سال: 2018

ISSN: 2156-7085,2156-7085

DOI: 10.1364/boe.9.002844