Spectra of Scattered Radiation at Points off the Beam Axis
نویسندگان
چکیده
منابع مشابه
An Off-Axis Neutrino Beam
1 Problem A typical high-energy neutrino beam is made from the decay of π mesons that have been produced in proton interactions on a target, as sketched in the figure below. Suppose that only positively charged particles are collected by the " horn ". The main source of neutrinos is then the decay π + → µ + ν µ. 1. Give a simple estimate of the relative number of other types of neutrinos than ν...
متن کاملBetatron Radiation from an Off-axis Electron Beam in the Plasma Wakefield Accelerator
In a plasma wakefield accelerator in the nonlinear regime the accelerated bunch electrons oscillate in a pure ion column. They emit strong synchrotron, also known as betatron radiation, in the keV to MeV photon range [1]. In previous experiments with a single electron bunch the oscillating electrons where distributed symmetrically about the beam axis or the ion column axis. However, with a driv...
متن کاملMeasurement of Coherent Off-axis Undulator Radiation as a Beam Diagnostic
* Corresponding author. Tel.: +301-405-4977. Email [email protected]. Abstract A diagnostic undulator is used to measure relative electron bunch lengths. The radiation produced by the short undulator is observed off-axis so that the beam is not interrupted. Wavelengths radiated which are longer than the bunch length are coherent and may be more intense than the shorter wavelengths by a facto...
متن کاملA Non-interrupting Electron Beam Diagnostic Using Coherent Off-axis Undulator Radiation
We propose a technique for measuring the length of an electron bunch from a linear accelerator without interrupting the electron beam. Bunch lengths are measured by observing off-axis undulator radiation. The wavelength of undulator radiation increases with the angle of emission. At angles as large as 10 degrees, the wavelength may be longer than the electron bunch, and as a result coherence ef...
متن کاملInvestigation of Scattered Radiation Dose at the Door of a Radiotherapy Vault When the Maze Intersects the Primary Beam
NCRP 151 provides very detailed examples demonstrating the necessary concerns for shielding a conventional radiotherapy vault with a maze where the useful beam is parallel to the maze. However, it provides little guidance on how to properly shield a vault with the maze-wall acting as part of a compound primary barrier. We have modeled a new radiotherapy vault with this configuration and assesse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiology
سال: 1959
ISSN: 0033-8419,1527-1315
DOI: 10.1148/72.1.107