Specificity of Heat-Stable Pseudomonal Proteases: Peptide Mapping by Reverse-Phase High Performance Liquid Chromatography
نویسندگان
چکیده
منابع مشابه
Factors influencing the performance of peptide mapping by reversed-phase high-performance liquid chromatography.
Factors controlling the performance of peptide mapping on reversed-phase columns were systematically evaluated. Performance criteria included resolution (peak capacity and selectivity), system reproducibility, sensitivity and analysis speed. Column configuration, characteristics of packing materials, mobile phase composition, operating variables and instrumental designs were found to influence ...
متن کاملAnalytical Peptide Mapping by High Performance Liquid Chromatography
Peptide mapping of underivatized tryptic digests of bovine and chick intestinal calcium-binding proteins has been accomplished by high performance liquid chromatography (HPLC). High precision analysis of nanomolar quantities of peptides were achieved in less than 1 h (recycle time). Peak resolution and definition are superior compared to conventional techniques and recoveries of both small (4-r...
متن کاملReverse-phase chromatography of polar biological substances: separation of catechol compounds by high-performance liquid chromatography.
Catecholamines and their metabolites have been separated isocratically by reverse-phase chromatography with aqueous (no organic solvent admixed) eluents. Unlike ion-exchange or ion-pair chromatography, mixtures of both acidic and basic substances can be separated in a single chromatographic run, because the retention is governed by hydrophobic interactions between the nonpolar moiety of the sol...
متن کاملDetermination of Fluconazole in Human Plasma by Reverse Phase High Performance Liquid Chromatography.
A rapid, simple and reproducible high performance liquid chromatographic method was developed and validated for determination of fluconazole in human plasma. The separation was performed on MZ C8 column (125 x 4 mm, 5 µm) using acetonitrile - potassium dihydrogen phosphate buffer (15 : 85, v/v), pH 3.0, as the mobile phase at a flow rate of 1.5 mL/min. The wavelength was set at 261 nm. The assa...
متن کاملFractionation of gibberellins in plant extracts by reverse phase high performance liquid chromatography.
In studies on endogenous plant gibberellins (GAs), reverse phase (Bondapak C(18)) high performance liquid chromatography (HPLC) has proved to be a useful method for the fractionation of plant extracts. The behavior of 18 authentic GAs in such a chromatographic system is described. The main factors determining chromatographic behavior are the degree and the position of hydroxylation of the GA. G...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Dairy Science
سال: 1989
ISSN: 0022-0302
DOI: 10.3168/jds.s0022-0302(89)79180-3