Specificity and Sensitivity of Ascitic Fluid Total Protein (AFTP) and Serum Ascitic Albumin Gradient (SAAG) in Diagnosis Etiology of Ascites
نویسندگان
چکیده
منابع مشابه
Role of serum-ascites albumin gradient in differential diagnosis of ascites.
BACKGROUND The classification of ascites as 'exudative' and 'transudative' based on ascitic fluid total protein (AFTP) has been challenged in many clinical conditions like cardiac ascites, patients on prolonged diuretic therapy and malignant ascites because it had poor diagnostic efficacy. These drawbacks have led to the development of another approach to classify ascites, which is based on Ser...
متن کاملIdentifying high and low serum-ascites albumin gradient in ascitic fluid by the point of care dipstick test
Objective: To evaluate the capability of ascitic fluid dipstick results for pH, glucose, and protein in order to predict a low serum-ascites albumin gradient (SAAG) at the bedside of the patient in the emergency department (ED). Methods: This prospective cross-sectional study was conducted during one year in the ED of Afzalipour hospital in Kerman, Iran. ...
متن کاملComparative utility of sero ascites albumin gradient and ascitic fluid total protein for differential diagnosis of ascites.
Ascites can be defined as the abnormal accumulation of fluid inside the peritoneal cavity. Earlier ascites was classified as transudative and exudative based on the total protein concentration of the ascitic fluid. The traditional concept of high protein ascites(> 2.5 g/dl) as exudate was questioned because: (a) the normal peritoneal fluid protein concentration is some times > 4 g/dl(1); (b) th...
متن کاملAnalysis of Serum Ascites Albumin Gradient Test in Ascitic Dogs
The aim of the study was to evaluate Serum Ascites Albumin Gradient (SAAG) in ascitic dogs. Study was conducted at Referral Veterinary Poly Clinic, Indian Veterinary Research Institute, Izatnagar. Sick dogs were brought with clinical signs suggestive of distended abdomen and inappetance. General clinical examination, biochemical, ultrasound examination, abdominocentesis and peritoneal fluid exa...
متن کاملAscitic fluid to serum bilirubin ratio for differentiation of exudates from transudates
Abstract Background: Regarding the diagnostic errors of the classic criteria including serum ascites albumin gradient (SAAG), total protein concentration and the adapted Light et al’s criteria in distinguishing transudate versus exudates, we evaluated the ascitic fluid to serum bilirubin ratio as a new criteria in this regard. We also evaluated whether the combination of bilirubin r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Fayoum University Medical Journal
سال: 2023
ISSN: ['2536-9474', '2536-9482']
DOI: https://doi.org/10.21608/fumj.2023.308071