Specific Creatinine Determination in Laboratory Animals Using the New Enzymatic Test Kit “Creatinine-PAP”
نویسندگان
چکیده
منابع مشابه
Specific creatinine determination in laboratory animals using the new enzymatic test kit "Creatinine-PAP".
The new Creatinine-PAP test kit from Boehringer Mannheim GmbH was evaluated for the determination of creatinine in dogs, rabbits, guinea pigs, rats, and mice. In comparison with methods based on the reaction with alkaline picrate, the enzymatic method gave the lowest serum creatinine values. The differences are caused by serum substances (non-creatinine chromogens) reacting with picric acid. No...
متن کاملA New Commercial Method for the Enzymatic Determination of Creatinine in Serum and Urine
biotimdase-deficient specimen in the autosampler. A sample cup containing phosphate buffer should be inserted between each sample suspected of having deficient or very low activity. Interfering substances such as sulfonamides, if present in a sample, can cause color development, such that a biotimdase-deficient specimen could exhibit color corresponding to normal activity and a normal specimen ...
متن کاملA new specific assay for urinary creatinine.
A new specific assay for urinary creatinine is described. The procedure is based on the separationof creatinine from other urinary componentsby Sephadexgel filtration, and subsequentmeasurementof the compoundat 235 nm against a phosphatebuffer blank. No interference by other substances has been encountered. The standard deviations in a series of assaysusing standard solutions are less than 2%, ...
متن کاملCatecholamine interference in enzymatic creatinine assays.
BACKGROUND Enzymatic creatinine assays are routinely used in clinical laboratories to provide more accurate estimated glomerular filtration rates and to avoid a perceived lack of analytical specificity associated with picrate (Jaffe) methods. Negative interferences with the enzymatic creatinine assay, which we noted in several patients on dopamine or dobutamine, prompted our further investigati...
متن کاملNew approaches with the Chem-1 creatinine determination.
Three modifications of the Chem-1 determination of serum creatinine were tested. Two different algorithms developed for compensating the interference of bilirubin were compared with the current one by analysing bilirubin-enriched albumin solutions and 82 icteric serum samples. A number of known other interfering substances were also tested. The modification involving parallel bichromatic measur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry and Laboratory Medicine
سال: 1987
ISSN: 1434-6621,1437-4331
DOI: 10.1515/cclm.1987.25.6.357