منابع مشابه
The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملthe effect of focal spot size on the spatial resolution of variable resolution x-ray ct scanner
background: a variable resolution x-ray (vrx) ct scanner provides a great increase in the spatial resolution. in vrx ct scanners, the spatial resolution of the system and its field of view (fov) can be changed according to the object size. one of the main factors that limit the spatial resolution of vrx ct scanner is the effect of the x-ray focal spot. materials and methods: a theoretical study...
متن کاملHard X-Ray Microscope With Submicrometer Spatial Resolution
A high-resolution hard x-ray microscope is described. This system is capable of detecting line features as small as 0.6 µm in width, and resolving line pairs 1.2-µm wide and 1.2-µm apart. Three types of two-dimensional image detectors are discussed and compared for use with hard x rays in high resolution. Principles of x-ray image magnification are discussed based on x-ray optics and diffractio...
متن کاملRecent developments in X-ray imaging with micrometer spatial resolution.
X-ray detectors for imaging with a spatial resolution in the micrometer and submicrometer range have been developed at synchrotron radiation sources since 1996. The detectors consist of a scintillator, a light microscopy optic and a charge-coupled device (CCD). The scintillator converts part of the X-ray stopped by a material into a visible-light image which is projected onto the CCD by the lig...
متن کاملExamining nanoparticle assemblies using high spatial resolution x-ray microtomography
An experimental system has been designed to examine the assembly of nanoparticles in a variety of process engineering applications. These applications include the harvesting from solutions of nanoparticles into green parts, and the subsequent sintering into finished components. The system is based on an x-ray microtomography with a spatial resolution down to 5 mm. The theoretical limitations in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2011
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927611005319