Sparse view cone beam X-ray luminescence tomography based on truncated singular value decomposition
نویسندگان
چکیده
منابع مشابه
A wavelet-based single-view reconstruction approach for cone beam x-ray luminescence tomography imaging.
Single-view x-ray luminescence computed tomography (XLCT) imaging has short data collection time that allows non-invasively and fast resolving the three-dimensional (3-D) distribution of x-ray-excitable nanophosphors within small animal in vivo. However, the single-view reconstruction suffers from a severe ill-posed problem because only one angle data is used in the reconstruction. To alleviate...
متن کاملCone Beam X-Ray Luminescence Tomography Imaging Based on KA-FEM Method for Small Animals
Cone beam X-ray luminescence tomography can realize fast X-ray luminescence tomography imaging with relatively low scanning time compared with narrow beam X-ray luminescence tomography. However, cone beam X-ray luminescence tomography suffers from an ill-posed reconstruction problem. First, the feasibility of experiments with different penetration and multispectra in small animal has been teste...
متن کاملOn the truncated multilinear singular value decomposition
In this report, we investigate the truncated multilinear singular value decomposition (MLSVD), proposed in De Lathauwer et al. (2000). Truncating the MLSVD results in an approximation, with a prescribed multilinear rank, to a tensor. We present a new error expression for an approximate Tucker decomposition with orthogonal factor matrices. From this expression, new insights are obtained which le...
متن کاملCollimated superfine x-ray beam based x-ray luminescence computed tomography.
X-ray luminescence computed tomography (XLCT) is a hybrid imaging modality with the potential to achieve a spatial resolution up to several hundred micrometers for targets embedded in turbid media with a depth larger than several millimeters. In this paper, we report a high spatial resolution XLCT imaging system with a collimated superfine x-ray beam in imaging the deeply embedded targets. A co...
متن کاملX-ray micromodulated luminescence tomography in dual-cone geometry.
We propose a scanning method utilizing dual-cone beams of x-rays to induce luminescence from nanophosphors and reconstruct the three-dimensional distribution of these particles in a biological sample or a small animal. For this purpose, x-rays are focused through a polycapillary lens onto a spot of a few micrometers in size. Such x-ray scanning can be point-wise performed to acquire photon emis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2018
ISSN: 1094-4087
DOI: 10.1364/oe.26.023233