Space Charge Accumulation at Material Interfaces in HVDC Cable Insulation Part I—Experimental Study and Charge Injection Hypothesis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Influence of Material Modification and Residues on Space Charge Accumulation in XLPE for DC Cable Application

Effects of cross-linking by-products (residues) of polyethylene on space charge accumulation and decay are investigated in the paper using the pulsed electro-acoustic technique. Space charge profiles have shown a great variation both in the charge initiation over the voltage ramping up process and later on long term stressing and decay (volts off) among the samples subjected to different condit...

متن کامل

Space Charge and Dc Dielectric Breakdown in Polymeric Insulation

Dielectric breakdown of solid insulation has been studied for many years but the mechanisms that cause breakdown have not been fully understood. Charge injection always occurs at high electric fields and especially under dc conditions. The presence of space charge in solid dielectrics will result in distortion of electric field distribution. Dielectric breakdown can be initiated in the region w...

متن کامل

Fabrication of Al2O3 Nano-Structure Functional Film on a Cellulose Insulation Polymer Surface and Its Space Charge Suppression Effect

Cellulose insulation polymer (paper/pressboard) has been widely used in high voltage direct current (HVDC) transformers. One of the most challenging issues in the insulation material used for HVDC equipment is the space charge accumulation. Effective ways to suppress the space charge injection/accumulation in insulation material is currently a popular research topic. In this study, an aluminium...

متن کامل

A Methodology for the Assessment of Hvdc-xlpe Cable Insulation

The purpose of this work is to present and to discuss a methodology for the assessment of materials intended to HVDC-XLPE cables, particularly as regards the evaluation of the effects of material formulation on space charge accumulation within the insulation. Sample design, testing method and protocol and criteria used for the material evaluation are specifically considered. It will be shown th...

متن کامل

Space Charge Accumulation under the Effects of Temperature Gradient on Solid Dielectric Dc Cable

It is well known that existence and accumulation of space charge within the insulating material poses threat to the reliability in the operation of dc power cables. When the cables are loaded under high voltage direct current (HVDC), temperature gradient is developed across the insulation material. In this paper, commercial ac XLPE power cables were used under an application voltage of 80 kV dc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2020

ISSN: 1996-1073

DOI: 10.3390/en13082005