Soudan 2 Data Acquisition and Trigger Electronics
نویسندگان
چکیده
منابع مشابه
Data Acquisition and Trigger Considerations
This note discusses requirements on data acquisition and triggering for the UT Maya Muon detector. The detector is described in a conceptual design report [1] (CDR). The present discussion is limited to the tracking system which is used to form event triggers and to measure muon trajectories; data from the Cherenkov system will be read out and recorded when a trigger generated by the tracking s...
متن کاملAtmospheric neutrinos in Soudan 2
allows a measurement which is independent of an absolute ux or exposure calculation. Soudan 2 is an iron calorimeter with di erent experimental systematics from the water Cherenkov detectors and with a di erent geometry and detection technique from from the Frejus experiment. A large veto shield placed against the cavern wall allows the identi cation of particles entering the detector from the ...
متن کاملATLAS Trigger and Data Acquisition: Capabilities and Commissioning
The ATLAS trigger system is based on three levels of event selection that selects the physics of interest from an initial bunch crossing rate of 40 MHz to an output rate of ∼200 Hz compatible with the offline computing power and storage capacity. During nominal LHC operations at a luminosity of 1034 cm−2s−1, decisions must be taken every 25 ns. The LHC is expected to begin operations with a pea...
متن کاملTrigger and Data Acquisition for the Super LHC
R&D is needed for LHC trigger and data acquisition systems if the LHC luminosity is increased to 10 cms. This upgrade, entitled the Super LHC (SLHC), would occur in the next decade. The physics triggers, the algorithms needed to provide these triggers against the substantially increased backgrounds and pile-up, and the types of electronics solutions that can support these more sophisticated alg...
متن کاملThe Mark-ii Data Acquisition and Trigger System*
The Mark-II Data Acquisition and Trigger system requirements and general solution are described. The solution takes advantage of the synchronous crossing times and low event rates of an electron positron collider to permit a very highly multiplexed analog scheme to be effective. The system depends on a two level trigger to operate with acceptable dead time. The trigger, multiplexing, data reduc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1985
ISSN: 0018-9499