Solvent Extraction and Spectrophotometric Determination of Thorium(IV) with Xylenol Orange
نویسندگان
چکیده
منابع مشابه
Solid Phase Spectrophotometric Determination Of Cobalt By Xylenol Orange
A simple and sensitive solid phase spectrophotometric method for the determination of cobalt is proposed based on the reaction between cobalt and xylenol orange (XO). The reaction product is fixed on the anionic exchanger resin sephadex QAE A-25 at pH= 5. The optical absorbance of the anionic gel like resin, packed in a 1.00 mm cell is directly measured at 588.0 nm. The linear range of calibrat...
متن کاملSimultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares
A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...
متن کاملSolvent Extraction and Spectrophotometric Determination of Magnesium by Paratoly l-2-Thenohydroxamic Acid and Quinalizarin
Magnesium is extracted with a chloroform solution of N-p-tolyl-2- thenohydroxamic acid (PTTHA) from aqueous solution of pH 9.5 .Mg-PTTHA complex is colourless and the colour is developed by adding quinalizarin into the extract. lmax and e of the complex are 590nm and 2.8´103 Lmol -1cm-1respectively.Most common ions do not interfere in the determination of magnesi...
متن کاملsimultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares
a partial least squares (pls) calibration model was developed for the simultaneous spectrophotometricdetermination of pb (ιι), cu (ιι) and ni (ιι) using xylenol orange as a chromogenic reagent. the parameterscontrolling behavior of the system were investigated and optimum conditions were selected. the calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...
متن کاملmultiwavelength pectrophotometric determination of stability constants of 4-(2– thiazolylazo) resorcinol (tar) with la3+, y3+ and th4+ in organic-water mixed solvents by chemometrics method & simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares calibration method
تشکیل کمپلکس های tarبا یون های لانتانیم, ایتریم و توریم در دمای 25 درجه، قدرت یونی ثابت 0.1 مولار و در ph ثابت در مخلوط حلال های اتانول – آب و استونیتریل – آب با استفاده از روش های اسپکتروفوتومتری مورد بحث و بررسی قرار گرفت. داده های اسپکتروفوتومتری با استفاده از نرم افزار squad پردازش شدند تا ثابت های تشکیل کمپلکس اندیکاتور – فلز را محاسبه کند. نتایج نشان می دهد که درصد حلال آلی در مخلوط حلال ...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nippon kagaku zassi
سال: 1968
ISSN: 0369-5387,2185-0917
DOI: 10.1246/nikkashi1948.89.11_1087