Solid-state electrochemical behavior of Keggin-type borotungstic acid single crystal
نویسندگان
چکیده
منابع مشابه
Mechanism of ‘‘Solid-State’’ Single-Crystal Conversion in Alumina
Single crystals of Al2O3 were reproducibly grown from an MgO-doped polycrystalline precursor. The single crystals were grown through controlled abnormal grain growth at temperatures between 16701 and 19451C. It was observed that CaO impurities segregated to the boundary between the single crystal and the polycrystalline region, and formed a wetting intergranular film. This type of film is requi...
متن کاملSolid–Solid Synthesis, Crystal Structure and Thermal Decomposition of Copper(II) Complex of 2-Picolinic Acid
The copper(II) complex [Cu(pic)2]·2H2O was synthesized with 2-picolinic acid (Hpic) and copper acetate as reactants by room temperature solid-solid reaction. The composition and structure of the complex was characterized by elemental analyses, single crystal X-ray diffraction, X-ray powder diffraction, FT-IR spectroscopy and thermogravimetry-differential scanning calor...
متن کاملNi2As2O7 pyrochlore nanomaterial: Solid state synthesis, crystal structure determination, crystal phase growth study and physical properties
Nanostructured Ni2As2O7 semiconductor samples were synthesized by a solid state method among As2O3 and Ni(NO3)2.6H2O raw materials at 650 °C (S1) and 750 °C (S2) as reaction temperatures. The synthesized nanomaterials were characterized by powder X-ray diffraction (PXRD) technique and F...
متن کاملNi2As2O7 pyrochlore nanomaterial: Solid state synthesis, crystal structure determination, crystal phase growth study and physical properties
Nanostructured Ni2As2O7 semiconductor samples were synthesized by a solid state method among As2O3 and Ni(NO3)2.6H2O raw materials at 650 °C (S1) and 750 °C (S2) as reaction temperatures. The synthesized nanomaterials were characterized by powder X-ray diffraction (PXRD) technique and F...
متن کاملAn all solid-state electrochemical electrolyte analyzer.
Ion-selective electrodes have been applied to analysis of blood electrolytes with some success. However, currently available ion-selective electrode systems tend to be elaborate and expensive. We describe a clinical electrolyte analyzer in which inexpensive ion-selective electrodes are used. The elec‘trodes are in the configuration of thin wires and are all solid in construction. They may be di...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Solid State Electrochemistry
سال: 2013
ISSN: 1432-8488,1433-0768
DOI: 10.1007/s10008-012-1983-1