Soft Microelectrode Linear Array for Scanning Electrochemical Microscopy
نویسندگان
چکیده
منابع مشابه
Soft microelectrode linear array for scanning electrochemical microscopy.
A linear array of eight individual addressable microelectrodes has been developed in order to perform high-throughput scanning electrochemical microscopy (SECM) imaging of large sample areas in contact regime. Similar to previous reports, the soft microelectrode array was fabricated by ablating microchannels on a polyethylene terephthalate (PET) film and filling them with carbon ink. Improvemen...
متن کاملSoft stylus probes for scanning electrochemical microscopy.
A soft stylus microelectrode probe has been developed to carry out scanning electrochemical microscopy (SECM) of rough, tilted, and large substrates in contact mode. It is fabricated by first ablating a microchannel in a polyethylene terephthalate thin film and filling it with a conductive carbon ink. After curing the carbon track and lamination with a polymer film, the V-shaped stylus was cut ...
متن کاملMicroelectrode Array Fabrication for Electrochemical Detection with Carbon Nanotubes
............................................................................................................................................. II Acknowledgements ........................................................................................................................... III Table of
متن کاملScanning Electrochemical Microscopy. 28. Bon-Selective Neutral CarriermBased Microelectrode Potent iometry
Electrodes for scanning ion-selective potentiometric microscopy (or potentiometric SECM) were developed and used to image local concentration profiles of NH4+, K+, and Zn2' ions. Neutral carrier-based micropipet ionselective electrodes with high spatial resolution (-2-3 pm) and fast response time (-300 ms) were fabricated and employed as potentiometric SECM tips, and highresolution ion-selectiv...
متن کاملFinger probe array for topography-tolerant scanning electrochemical microscopy of extended samples.
Scanning electrochemical microscopy with soft microelectrode array probes has recently been used to enable reactivity imaging of extended areas and to compensate sample corrugation perpendicular to the scanning direction. Here, the use of a new type of microelectrode arrays is described in which each individual microelectrode can independently compensate corrugations of the sample surface. It c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Chemistry
سال: 2010
ISSN: 0003-2700,1520-6882
DOI: 10.1021/ac1019304