Soft Inductive Coil Spring Strain Sensor Integrated with SMA Spring Bundle Actuator
نویسندگان
چکیده
منابع مشابه
Open-Coil Retraction Spring
Sliding mechanic has become a popular method for space closure with developments in preadjusted edgewise appliance. Furthermore, various space closing auxiliaries have been developed and evaluated extensively for their clinical efficiency. Their effectiveness enhanced with optimum force magnitude and low-load deflection rate (LDR)/force decay. With the advent of NiTi springs in orthodontics, LD...
متن کاملMotion Analysis of In-pipe Robot Based on SMA Spring Actuator
The in-pipe robots play significant role for applications like inspection of pipes or wearing of cables and materials, etc. The paper deals with motion analysis of in-pipe robot, whose actuator is based on shape memory effect. At first, the principle of motion and design solution of experimental in-pipe robot is introduced. Then the mathematical model is establish by means of Newton ́s mechanics...
متن کاملInductive Inference Research Status , Spring 1967
Previously, four theories of inductive inference were proposed, and the present work is concerned with putting these theories on a firmer theoretical footing. The four theories are now found to be effectively equivalent, at varying levels of rigor. It is shown that for sufficiently long sequences of symbols, the theories actually do give the correct probabilities for future symbols. Attempts ar...
متن کاملMacroscopic Sma Wire Bundle Actuator / Sensor System : Design , Measurement , Control Approach
Prestrainend shape memory alloys (SMA) change their length when heated above their transformation temperature. Based on this property this paper presents the design of macroscopic SMA actuators scalable in force and length that keeps up a short cool down time to guarantee a high frequency of contraction/stress cycles and the possibility of arranging the fixings in any direction. A new model of ...
متن کاملSpring coil retraction in coil occlusion of persistent ductus arteriosus.
AIMS To present the short and intermediate term results of coil occlusion of persistent ductus arteriosus and the results of radiographic measurements of spring coils implanted to treat patent ducts. PATIENTS 22 children underwent coil occlusion. Their ages ranged from 2 years 9 months to 12 years 10 months (mean (SD) age, 6.5 (3.6) years). The duct diameter ranged from 1.0 to 3.5 mm at the n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2021
ISSN: 1424-8220
DOI: 10.3390/s21072304