SNR in MI Catheter Receivers for MRI

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synchronization and SNR Estimation in M-PSK Wireless Receivers

Coherent M-PSK reception in M-PSK receivers is achieved through use of two main PLLs (Phase Lock Loops): the carrier synchronization PLL (carrier PLL for short) and the symbol timing synchronization PLL (symbol PLL for short). An SNR (Signal-to-Noise Ratio) estimation module is also typically present in the receiver. In this paper we shall present an overview of contemporary coherent M-PSK rece...

متن کامل

Multifunctional interventional devices for MRI: a combined electrophysiology/MRI catheter.

The design and application of a two-wire electrophysiology (EP) catheter that simultaneously records the intracardiac electrogram and receives the MR signal for active catheter tracking is described. The catheter acts as a long loop receiver, allowing for visualization of the entire catheter length while simultaneously behaving as a traditional two-wire EP catheter, allowing for intracardiac el...

متن کامل

Design Principles for Insulated Internal Loopless Mri Receivers

A theoretical analysis of insulated internal loopless MRI receivers is presented. Insulated loopless receivers are ideal for local, high resolution imaging of the vasculature and other internal organs. However, there are currently no analysis techniques or design principles for these devices. By using a Galerkin method of moments combined with an application of the volume equivalence theorem, w...

متن کامل

Iterative per-Frame Gain and SNR Estimation for DVB-S2 receivers

In future 2nd-generation digital video broadcasting (DVB-S2) receivers working in ACM (Adaptive Coded Modulation) mode, an unknown residual gain must be estimated before the low-density parity-check (LDPC) decoding stage. Moreover, the signal-to-noise ratio (SNR) has to be estimated also, since the iterative decoding algorithms, such as those employed to decode LDPC codes, require its knowledge...

متن کامل

Model-based Catheter Segmentation in MRI-images

Accurate and reliable segmentation of catheters in MR-guided interventions remains a challenge, and a step of critical importance in clinical workflows. In this work, under reasonable assumptions, mechanical model based heuristics guide the segmentation process allows correct catheter identification rates greater than 98% (error62.88 mm), and reduction in outliers to one-fourth compared to the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Sensors Journal

سال: 2016

ISSN: 1530-437X,1558-1748,2379-9153

DOI: 10.1109/jsen.2015.2500226