Smear layer removal in canals shaped with reciprocating rotary systems

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Smear layer removal in canals shaped with reciprocating rotary systems

The aim was to assess the presence of smear layer after canal instrumentation with two reciprocating rotary systems and a continuous motion one. Thirty canals were shaped with Reciproc, WaveOne or Mtwo systems. Smear layer was assessed following a three value scale at coronal, middle and apical levels with a scanning electron microscopy. Reciproc scores: coronal third, 20% of the cases: 0, 60%:...

متن کامل

Ex-vivo Smear Layer Removal Efficacy of Two Activated Irrigation Techniques After Reciprocating Instrumentation in Curved Canals

Introduction This study aimed to compare the effectiveness of two activated irrigation techniques in removing the smear layer after single-file reciprocating instrumentation in curved canals. Materials and Methods Sixty distobuccal roots of maxillary molars were standardized to create a closed system, and then instrumented using WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) in...

متن کامل

Shaping ability of reciprocating single-file and full-sequence rotary instrumentation systems in simulated curved canals

OBJECTIVE The purpose of this study was to evaluate the shaping ability of three nickel-titanium systems in simulated curved canals. MATERIALS AND METHODS Sixty simulated canals were prepared to apical size 25 with Reciproc, S5, and twisted file (TF) instruments. Standardized pre and postoperative images were taken using a digital camera, were superimposed and aberrations were recorded. Mater...

متن کامل

Effects on smear layer and debris removal with varying volumes of 17% REDTA after rotary instrumentation.

The purpose of this study was to quantify the volume of 17% ethylene diamine tetra-acetic acid (EDTA) needed to efficiently remove the smear layer after rotary instrumentation, and to determine if additional irrigation has any effect on debris removal. Forty single canal teeth were instrumented with ProFile GT rotary instruments. Experimental groups were irrigated with 1, 3, or 10 ml of 17% EDT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical and Experimental Dentistry

سال: 2013

ISSN: 1989-5488

DOI: 10.4317/jced.51170