Smartphone-based intraocular lens microscope
نویسندگان
چکیده
منابع مشابه
Confocal thermal-lens microscope.
The use of a confocal detection scheme in a dual-beam thermal-lens microscope is presented. The scheme allows the measurement of absorption factors down to 1.2 x 10(-7) in a 0.35-microm3 volume by use of a heating laser power of 100 mW incident upon the sample. Results are presented that prove that a 450-nm axial resolution is possible when a 1.2 water immersion objective lens with a N.A. of 1....
متن کاملSuperlensing microscope objective lens.
Conventional microscope objective lenses are diffraction limited; they cannot resolve subdiffraction features of a size smaller than 250-300 nm under white lighting condition. New innovations are required to overcome this limitation. In this paper, we propose and demonstrate a new superlensing objective lens that possesses a resolution of 100 nm, which is a two-times resolution improvement over...
متن کاملIntraocular lens calculation for aspheric intraocular lenses.
PURPOSE To evaluate the possible benefits of biometry and ray-tracing intraocular lens (IOL) calculation for aspheric aberration-correcting IOLs. SETTING Private eye clinic in Germany. DESIGN Retrospective consecutive case series. METHODS Eyes with 3 different aberration-correcting IOLs were reviewed. Before surgery, the axial length, corneal thickness, anterior chamber depth, crystalline...
متن کاملAnterior Segment Intraocular Lens
Currently, posterior chamber intraocular lenses (IOLs) correct totally or partially spherical aberrations. In this article we present the visual results of a prospective multicentre study evaluating the Micro AY IOL correcting 0.11μm of spherical aberration, which is a good compromise between optimal vision and a consistent depth of focus. We evaluated 124 eyes that were operated on using bi-ma...
متن کاملPiggyback intraocular lens implantation.
The piggyback method of implanting two intraocular lenses in one eye has been successfully expanded to address pseudophakic refractive error in normal eyes and eyes that have undergone post-penetrating keratoplasty. Piggyback implantation has been combined with the use of newly available minus-power lenses to provide appropriate power for a cataract patient with keratoconus, as well as to corre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Ophthalmology
سال: 2020
ISSN: 0301-4738
DOI: 10.4103/ijo.ijo_2032_19