Smart Local Backup Protection for Smart Substation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Smart Local Backup Protection for Smart Substation

Received Apr 11, 2017 Revised Apr 28, 2017 Accepted Jun 17, 2017 This paper presents a novel smart local backup protection SLBP used for the support and backup of the protective relays in a smart substation. The proposed SLBP is based on the IEC61850 standards and the concept consists of the acquisition of Generic Object Oriented Substation Event GOOSE used for tripping and interlocks exchange ...

متن کامل

Comprehensive Evaluation of Reliability of Protection System in Smart Substation

The reliability of smart substations has a great significance on the safety and stability of smart grid operation. Taking the protection system in smart substation as an example, this paper constructs comprehensive reliability models to evaluate the reliability of smart substations with different architectures. The paper first illustrates two important aspects which affect the reliability of th...

متن کامل

Distribution Substation Automation in Smart Grid

Distribution Substation Automation in Smart Grid Substation Automation (SA) can provide integral functions to the distribution grid automation. As more IED devices are installed to the distribution network, the need for IED management, control, and the corresponding advanced application operation is a growing imperative. Moreover, the Smart Grid applications, such as the Integrated Voltage and ...

متن کامل

Local Derivative Pattern with Smart Thresholding: Local Composition Derivative Pattern for Palmprint Matching

Palmprint recognition is a new biometrics system based on physiological characteristics of the palmprint, which includes rich, stable, and unique features such as lines, points, and texture. Texture is one of the most important features extracted from low resolution images. In this paper, a new local descriptor, Local Composition Derivative Pattern (LCDP) is proposed to extract smartly stronger...

متن کامل

Smart Machine Protection System*

A Machine Protection System implemented on the SLC automatically controls the beam repetition rates in the accelerator so that radiation or temperature faults slowthe repetition rate to bring the fault within tolerance without shutting down the machine. This process allows the accelerator to aid in the fault diagnostic process, and the protection system automatically restores the beams back to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Electrical and Computer Engineering (IJECE)

سال: 2017

ISSN: 2088-8708,2088-8708

DOI: 10.11591/ijece.v7i5.pp2321-2328