Small Total Dose Measurement System for SOHLA-1 and SDS-1
نویسندگان
چکیده
منابع مشابه
DEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES
Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...
متن کاملDetermining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1
Background: Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for 131Cs source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the 131Cs Model CS-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage ...
متن کاملDose calculations accuracy of TiGRT treatment planning system for small IMRT beamlets in heterogeneous lung phantom
Background: Accurate dose calculations in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS). In the current study, the dose calculation accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calculations. Materials and Methods: The head of Siemens Oncor-impression linac...
متن کامل1 Advanced Total Lab Automation System ( ATLAS )
In modern analytical chemistry not only do new measurement principles have to be investigated but newly found techniques also need to be developed into integrated and more and more automated analytical solutions. Exploring new techniques in research and development (R&D) environments mostly means designing different setups incorporating a huge variety of different equipment. Whether this hardwa...
متن کاملSmall field size dose-profile measurements: A comparison between Eclipse™ treatment planning system with NIPAM polymer gel dosimeter dose measurement
Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, SPACE TECHNOLOGY JAPAN
سال: 2009
ISSN: 1347-3840
DOI: 10.2322/tstj.7.tr_2_27