منابع مشابه
Testing small clutch size models with Daphnia.
Life-history theory predicts that for small clutches, variance in egg size (between individuals) should decrease in a predictable invariant manner as clutch size increases. To test this, we studied Daphnia magna at 350 different food treatments and recorded the number of eggs and the volume of each egg for their first clutch. As predicted, we found that the relationship between clutch size and ...
متن کاملFatigue Testing
Fatigue is the progressive, localized, permanent structural change that occurs in materials subjected to fluctuating stresses and strains that may result in cracks or fracture after a sufficient number of fluctuations. Fatigue fractures are caused by the simultaneous action of cyclic stress, tensile stress and plastic strain. If any one of these three is not present, fatigue cracking will not i...
متن کاملFatigue Device for Testing Ankle Joint Endoprostheses
The paper proposes a model of a fatigue device for testing dedicated to ankle prostheses. The concept of the testing device relies on two aspects: almost any type of ankle prosthesis can be tested on it and it has to work on INSTRON axial-torsion testing machine. Starting from these requirements, a 3D functional assembly that reproduces the real movement of the ankle joint during gait cycle has...
متن کاملT3-Plot for Testing Spherical Symmetry for High-Dimensional Data with a Small Sample Size
High-dimensional data with a small sample size, such as microarray data and image data, are commonly encountered in some practical problems for which many variables have to be measured but it is too costly or time consuming to repeat the measurements for many times. Analysis of this kind of data poses a great challenge for statisticians. In this paper, we develop a new graphical method for test...
متن کاملFatigue testing median sternotomy closures.
OBJECTIVE Sternal dehiscence is commonly due to wire cutting through bone. With a biological model, we measured the rate of cutting through bone, of standard steel wire closure, peristernal steel wire, figure-of-eight closure, polyester and sternal bands sternotomy closure techniques. METHODS Polyester, figure-of-eight, peristernal and sternal band closures were tested against standard closur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of Japan Society of Spring Engineers
سال: 1976
ISSN: 0385-6917,1348-1479
DOI: 10.5346/trbane.1976.24