Small High Resolution Gamma Camera for Radio-guided Surgery

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera

Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution.  The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...

متن کامل

A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging.

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct ...

متن کامل

Minimally invasive radio-guided surgery for hyperparathyroidism: an experience with Tc-99m Sestamibi

  Introduction: Radio-guided parathyroid surgery along with other minimally invasive surgeries constitutes the main surgical treatment procedures for different kinds of hyperparathyroidism.  In this article we have reported our experience of radio-guided parathyroid surgery using Tc-99m sestamibi. Methods: Ten patients with hyperparathyroidism included in our study. ...

متن کامل

Characterisation of a high resolution small field of view portable gamma camera.

A handheld, high-resolution small field of view (SFOV) pinhole gamma camera has been characterised using a new set of protocols adapted from standards previously developed for large field of view (LFOV) systems. Parameters investigated include intrinsic and extrinsic spatial resolution, spatial linearity, uniformity, sensitivity, count rate capability and energy resolution. Camera characteristi...

متن کامل

Double Aperture Camera for High Resolution Measurement

In the domain of machine vision, the measurement of length is done using cameras where the accuracy is directly proportional to the resolution of the camera and inversely to the size of the object. Since most of the pixels are wasted imaging the entire body as opposed to just imaging the edges in a conventional system, a double aperture system is constructed to focus on the edges to measure at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 2001

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.kj00001357621