Investigation of Neutron Contamination of Flattening Filter and Flattening Filter-Free 10-MV Photon Beams in Elekta InfinityTM Accelerator
Introduction: This study aimed to measure the neutron contamination of flattening filter (FF) and flattening filter-free (FFF) 10-MV photon beams delivered by the Elekta InfinityTM accelerator. Material and Methods: The photoneutron spectrum produced by the Linac head was evaluated using a Monte Carlo (MC) simulation. The geometry ...
متن کاملOn flattening filter‐free portal dosimetry
Varian introduced (in 2010) the option of removing the flattening filter (FF) in their C-Arm linacs for intensity-modulated treatments. This mode, called flattening filter-free (FFF), offers the advantage of a greater dose rate. Varian's "Portal Dosimetry" is an electronic portal imager device (EPID)-based tool for IMRT verification. This tool lacks the capability of verifying flattening filter...
متن کاملDetector comparison for small field output factor measurements in flattening filter free photon beams.
PURPOSE The applicability of various detectors for small field dosimetry and whether there are differences in the detector response when irradiated with FF- and FFF-beams was investigated. MATERIALS AND METHODS Output factors of 6 and 10 MV FF- and FFF-beams were measured with 14 different online detectors using field sizes between 10 × 10 and 0.6 × 0.6 cm(2) at a depth of 5 cm of water in is...
متن کاملCommissioning of small field size radiosurgery cones in a 6-MV flattening filter-free beam.
This study aimed to describe the commissioning of small field size radiosurgery cones in a 6-MV flattening filter free (FFF) beam and report our measured values. Four radiosurgery cones of diameters 5, 10, 12.5, and 15 mm supplied by Elekta Medical were commissioned in a 6-MV FFF beam from an Elekta Versa linear accelerator. The extraction of a reference signal for measuring small fields in sca...
متن کاملEffect of dose rate on antitumor activity in hypoxic cells by using flattening filter free beams
Background: Recently, the Flattening Filter Free (FFF) beams, which allow a dose rate increase of up to four times compared to the normal dose rate, have been incorporated into radiation therapy machines. The aim of this study is to evaluate antitumor activity in hypoxic cells irradiated with different dose rates using FFF beams and to identify the casual mechanism for cellular damage during ir...