Sloshing characteristics of a flowing liquid in a tank. 2nd report. Frequency response characteristics and sloshing suppression.
نویسندگان
چکیده
منابع مشابه
Transient Response of Sloshing Fluid in a Three Dimensional Tank
Sloshing waves in moving tanks have been studied numerically, theoretically and experimentally in the past several decades. Most reported studies have been for tanks excited by forcing motion in a limited number of directions and with fixed excitation frequencies throughout the forcing. In the present study, a time-independent finite difference method is used to simulate fluid sloshing in the t...
متن کاملSloshing reduction effect of splitting wall in cylindrical tank
1 Central Research Institute of Electric Power Industry, 1646,Abiko, Abiko, Chiba, Japan 2 Professor, Disaster Prevention Research Institute ,Kyoto University, Gokasho, Uji, Kyoto, Japan 3 Idemitsu Engineering Co. , Ltd, Mihama, Chiba, Japan Email: [email protected],[email protected], [email protected], [email protected] ABSTRACT : Man...
متن کاملSloshing, Steklov and corners I: Asymptotics of sloshing eigenvalues
This is the first in a series of two papers aiming to establish sharp spectral asymptotics for Steklov type problems on planar domains with corners. In the present paper we focus on the two-dimensional sloshing problem, which is a mixed Steklov-Neumann boundary value problem describing small vertical oscillations of an ideal fluid in a container or in a canal with a uniform cross-section. We pr...
متن کاملLiquid sloshing in a horizontally forced vessel with bottom topography
This paper presents a numerical study of the free-surface evolution for inviscid, incompressible, irrotational, horizontally forced sloshing in a twodimensional rectangular vessel with an inhomogeneous bottom topography. The numerical scheme uses a time-dependent conformal mapping to map the physical fluid domain to a rectangle in the computational domain with a time-dependent aspect ratio Q(t)...
متن کاملEvaluation of Sloshing Load Acting on Fixed Roof of Liquid Storage Tank Based on Sph Simulation
It is difficult to evaluate the sloshing load acting on a fixed roof of tank because it depends on the collision of the liquid to the roof. In this paper, the SPH simulation was introduced to evaluate the load acting on a fixed roof. The results obtained by the simulation showed good agreement with those obtained from other method. In addition, the effect of the roof-liquid clearance on the slo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
سال: 1988
ISSN: 0387-5024,1884-8354
DOI: 10.1299/kikaic.54.1637