منابع مشابه
OPTIMEX: Measurement of Detonation Front Curvature with a Passive Fiber Optical System
The ability of a newly developed independent passive optical system OPTIMEX to measure the detonation front curvature is demonstrated on charges of pressed explosive A-IX-1 (RDX/ceresin-stearin mixture with 95/5 wt.%). The charges, with length to diameter ratios of from one to four, were prepared from cylinders with diameters of 21 mm, 30 mm, 40 mm and 50 mm pressed to a density of 1.66 g/cm3. ...
متن کاملHybrid curvature and gradient wave-front sensor.
A new wave-front sensor for adaptive optics that gives signals for the curvature and the two gradient components of the wave front simultaneously is proposed. The sensor uses quad cells placed at the foci of an array of astigmatic lenslets, giving three intensity-normalized differential signals. The parameters of a single subdetector are optimized to maximize the curvature signal. The performan...
متن کاملDiamond patterns in the cellular front of an overdriven detonation.
A nonlinear integral-differential equation describing the cellular front of an overdriven detonation is obtained by an analysis carried out in the neighborhood of the instability threshold. The analysis reveals both an unusual mean streaming motion, resulting from the rotational part of the oscillatory flow, and pressure bursts generated by the crossover of cusps representative of Mach stems pr...
متن کاملEffect of Porous Thrust Surfaces on Detonation Transition and Detonation Tube Impulse
As pulse detonation engine development matures, it becomes increasingly important to consider how practical details such as the implementation of valves and nozzles will affect performance. Inlet valve timing and valveless inlet designs may result in flow of products back upstream and, consequently, reduction in impulse over the ideal case. Although proper inlet design or operation under flowin...
متن کاملCurvature analyses of the corneal front and back surface.
In 25 eyes, age range 60-80 years, in purpose of preoperative treatment prior to cataract surgery, measurements of the radius of curvature as well as main meridians of the anterior and posterior corneal surfaces were performed. Average value of the curvature of the anterior corneal surface (R1) was R1 = 7.84 mm, while posterior radius (R2) was 6.4 mm. Main meridian of the anterior corneal surfa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Propellants, Explosives, Pyrotechnics
سال: 1997
ISSN: 0721-3115,1521-4087
DOI: 10.1002/prep.19970220408