Size-adaptable “Trellis” structure for tailored MRI coil arrays
نویسندگان
چکیده
منابع مشابه
Array compression for MRI with large coil arrays.
Arrays with large numbers of independent coil elements are becoming increasingly available as they provide increased signal-to-noise ratios (SNRs) and improved parallel imaging performance. Processing of data from a large set of independent receive channels is, however, associated with an increased memory and computational load in reconstruction. This work addresses this problem by introducing ...
متن کامل3-D RF Coil Design Considerations for MRI
High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...
متن کاملMaxwell's Equation Tailored Reverse Method of Obtaining Coil Sensitivity for Parallel MRI
Introduction: A new method is proposed to obtain noise-free RF coil sensitivity maps. This is highly desirable, considering the fact that the sensitivity encoding (SENSE)[1] method imposes ultimate dependence of successful full FOV image reconstruction on the correct sensitivity map of each individual coil. The proposed method differs from traditional methods in that, instead of refining the me...
متن کاملAutomatic Coil Selection for SENSE Imaging with Large Coil Arrays
Introduction Parallel imaging using coil arrays with large number of receive elements allows improved imaging performance and increased SNR [1, 2]. However, the use of a large number of coil elements can lead to memory storage problems and to increased reconstruction times. Several techniques for data reduction were presented, realized either by linear combination of the original coil data or b...
متن کاملCalculation of SAR for Transmit Coil Arrays.
Transmit coil arrays allowing independent control of individual coil drives facilitate adjustment of the B(1) field distribution, but when the B(1) field distribution is changed the electric field and SAR distributions are also altered. This makes safety evaluation of the transmit array a challenging problem because there are potentially an infinite number of possible field distributions in the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2018
ISSN: 0740-3194
DOI: 10.1002/mrm.27637