Singularity image method for electrical impedance tomography of bubbly flows
نویسندگان
چکیده
منابع مشابه
Singularity image method for electrical impedance tomography of bubbly flows
A singularity image method is applied to the electrical impedance tomography of gas–liquid flows in a two-dimensional circular domain. Algorithms that use analytic complex functions, dipoles and the Milne-Thomson circle theorem are described. Numerical experiments are provided to demonstrate the robustness of this technique. Numerical results show excellent reconstruction properties. (Some figu...
متن کاملMeasurement of near-wall stratified bubbly flows using electrical impedance
The impedance measurement between a pair of flush-mounted electrodes was used to measure the characteristics of a stratified near-wall bubbly flow. The variation in cross electrode impedance with liquid layer thickness and mixture void fraction was examined using numerical simulations and static experiments. The experimental realization of the measurement system was used to measure the solid fr...
متن کاملApplications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملImage Theory for Electrical Impedance Tomography
The first step of medical treatment is the diagnosis. This investigation is focused on some fundamental mathematical and physical characteristics of such diagnostic tool, namely the Electrical Impedance Tomography (EIT), a subject of great scientific and public interest (Holder, 2005; Brown, 2003; Lionheart, 2004). The basic EIT’s assumption is that different biological tissues can be distingui...
متن کاملTemporal image reconstruction in electrical impedance tomography.
Electrical impedance tomography (EIT) calculates images of the body from body impedance measurements. While the spatial resolution of these images is relatively low, the temporal resolution of EIT data can be high. Most EIT reconstruction algorithms solve each data frame independently, although Kalman filter algorithms track the image changes across frames. This paper proposes a new approach wh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Inverse Problems
سال: 2003
ISSN: 0266-5611,1361-6420
DOI: 10.1088/0266-5611/19/4/309