Single-Stage Orbital Socket Reconstruction Using the Oversized Dermis Fat Graft and the 22 mm Silicone Orbital Implant after an Extended Enucleation
نویسندگان
چکیده
منابع مشابه
Autogenous dermis-fat orbital impant for anophthalmic socket.
To our knowledge, there is no report of dermis-fat graft (DFG) implant for orbital reconstruction from Oman. We hereby presented a case report of a 10-year-old boy with a blind and painful left eye secondary to penetrating eye injury presented with implant extrusion following evisceration with a polymethyl methacrylate implant. The evisceration procedure was converted to enucleation and a DFG o...
متن کاملOrbital growth after unilateral enucleation in infancy without an orbital implant.
PURPOSE To measure the volume of the anophthalmic orbit in adults who had undergone enucleation during infancy and to determine its growth. METHODS The orbital volume in 5 adults who had undergone unilateral enucleation during infancy without an orbital implant was measured on x-ray computed tomography images. Comparisons were made between the anophthalmic and normal sides. In addition, we ev...
متن کاملIndications and results in anophthalmic socket reconstruction using dermis-fat graft
OBJECTIVES To present the indications for a dermis-fat graft in anophthalmic socket reconstruction and evaluate the results of this procedure. DESIGN Retrospective review, interventional case series. METHODS In our study, there were 41 patients who received either primary or secondary dermis-fat graft between August 1, 2007 and July 31, 2012 at Songklanagarind Hospital. RESULTS The type o...
متن کاملTreatment of Intractable Orbital Implant Exposure with Scleral Melting By Secondary Implant of Dermis Fat Graft-A Case Report
A 30 year old female with absolute glaucoma status post-evisceration developed recurrent orbital implant exposure and scleral melting. We successfully treated the large conjunctiva defect by utilizing secondary implant of dermis fat graft for tissue growth and tension-free conjunctiva closure. The patient was satisfied with the postoperative outcome, and no major complications were observed in ...
متن کاملMeasurement of Orbital Volume after Enucleation and Orbital Implantation
INTRODUCTION This article reports experience relating to the measurement of orbital volume by means of cone beam computed tomography (CBCT) and Cranioviewer program software in patients who have undergone enucleation and orbital implantation. PATIENTS AND METHODS CBCT scans were made in 30 cases, 10 of which were later excluded because of various technical problems. The study group therefore ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Case Reports in Ophthalmological Medicine
سال: 2018
ISSN: 2090-6722,2090-6730
DOI: 10.1155/2018/8954193