Single-phase linear actuator with semi-closed magnetic circuit.
نویسندگان
چکیده
منابع مشابه
Semi-automated closed-circuit bladder wash-out pump.
write: A pump has been constructed as a possible solution to a problem posed by one of us (D.W.)-namely, to produce a device which would wash out the bladder after prostatectomy vwithout breaking the closed drainage system (which could result ia an infection) and which could be used by relatively unskilled staff. The pump with its associated valves is composed of only two parts-a piston and a c...
متن کاملNon-Linear Dynamics Generating Theta Phase Precession in Hippocampal Closed Circuit and Generation of Episodic Memory
We propose a hypothesis for the neural mechanism underlying theta phase precession of place cell firing, based on phase locking by mean field interactions in a coupled-oscillator system, followed by inheritance through the hippocampal circuit. It is demonstrated that the temporal pattern inherited through the network can result in encoding of the temporal sequence of experience as asymmetric co...
متن کاملAn Innovative Simple Test Circuit for Single-Phase Short Circuit Making Test of High-Voltage Switching Devices
Nowadays, high-voltage circuit breakers have reached such high short-circuit capabilities that testing them under the full rated voltage is generally not possible with direct tests, and they are conducted by using the synthetic test methods. Although the phenomena associated with making tests is of particular importance especially in case of load break switches, but making tests are rather d...
متن کاملLinear Systems with Actuator Nonlinearities
This paper applies nonlinear 3t, control techniques to linear systems with actuator nonlinearities. In [3], this was treated under the certainty equivalence assumption. The control design produces a finite dimensional measurement feedback controller which is computable online provided certain conditions are met. In this paper, we do not use certainty equivalence theory. Instead, we use the more...
متن کاملMagnetic actuator design for single-axis micro-gyroscopes
An innovative magnetically levitated system design is presented in this paper. The proof mass, used as the seismic detection components for gyroscopes, is levitated by the presented micro-coil actuator so that the concerns that mechanical fatigue, asymmetry and misalignments, which are inevitably present in the traditional mechanical springs design, can be ruled out. In addition, the limited ra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Industry Applications
سال: 1988
ISSN: 0913-6339,1348-8163
DOI: 10.1541/ieejias.108.749