"Ultrathin" DSAEK tissue prepared with a low-pulse energy, high-frequency femtosecond laser.
PURPOSE To evaluate the endothelial cell survival and stromal bed quality when creating deep stromal cuts with a low-pulse energy, high-frequency femtosecond laser to produce "ultrathin" tissue for Descemet stripping automated endothelial keratoplasty. METHODS Seventeen corneas were used for this study. Five corneas were cut with the laser at a depth of 420 to 500 μm to produce a tissue thick...
متن کاملHistologically proven epithelial ingrowth in failed Descemet stripping automated endothelial keratoplasty (DSAEK) managed by repeat DSAEK
PURPOSE To report a case of corneal graft failure due to epithelial ingrowth after an uneventful combined Descemet stripping automated endothelial keratoplasty (DSAEK) and phacoemulsification cataract surgery with intraocular lens implant treated successfully with a repeat DSAEK. METHODS A 77-year-old male patient underwent combined DSAEK and phacoemulsification with intraocular lens implant ...
متن کاملTectonic DSAEK for the Management of Impending Corneal Perforation
Purpose. To report a case of severe corneal thinning secondary to dry eye treated with a tectonic Descemet stripping automated lamellar keratoplasty (DSAEK) and amniotic membrane graft. Methods. A 72-year-old man with a history of long standing diabetes mellitus type 2 and dry eye presented with 80% corneal thinning and edema on the right eye and no signs of infectious disease, initially manage...
متن کاملSubconjunctival Emphysema After Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)
DSAEK has recently evolved as a preferred method in place of PKP. After DSAEK, we experienced subconjunctival emphysema, decreased air bubble in the AC and low IOP. This could lead to complications, higher rate of dislocation or infection. We should control the wound closure with suture when in doubt.
متن کاملCombined use of a femtosecond laser and a microkeratome in obtaining thin grafts for Descemet stripping automated endothelial keratoplasty: an eye bank study.
PURPOSE To evaluate the use of a femtosecond laser combined with a microkeratome in the preparation of posterior corneal disks for Descemet stripping automated endothelial keratoplasty (DSAEK). METHODS This experimental study involved ultrathin DSAEK tissue preparation of 22 donor corneas unsuitable for transplantation. The first cut was performed with an Intralase® FS60 laser and the second ...