Single-crystal energy-dispersive Laue-type experiments
نویسندگان
چکیده
منابع مشابه
Stigmatic X-ray imaging using a single spherical Laue crystal
We propose a crystal configuration using a single Laue spherical crystal for imaging applications. A crystal in Laue geometry set to focus a divergent beam in the meridional (diffraction) plane, but does not focus in the sagittal plane. A transmission object placed in the beam is imaged with different horizontal and vertical aspect ratio, but it is possible to find a configuration with similar ...
متن کاملHigh-resolution Laue-type DuMond curved crystal spectrometer.
We report on a high-resolution transmission-type curved crystal spectrometer based on the modified DuMond slit geometry. The spectrometer was developed at the University of Fribourg for the study of photoinduced X-ray spectra. K and L X-ray transitions with energies above about 10 keV can be measured with an instrumental resolution comparable to their natural linewidths. Construction details an...
متن کاملSingle-shot full strain tensor determination with microbeam X-ray Laue diffraction and a two-dimensional energy-dispersive detector
The full strain and stress tensor determination in a triaxially stressed single crystal using X-ray diffraction requires a series of lattice spacing measurements at different crystal orientations. This can be achieved using a tunable X-ray source. This article reports on a novel experimental procedure for single-shot full strain tensor determination using polychromatic synchrotron radiation wit...
متن کاملAn improved method for calibrating time-of-flight Laue single-crystal neutron diffractometers
A robust and comprehensive method for determining the orientation matrix of a single-crystal sample using the neutron Laue time-of-flight (TOF) technique is described. The new method enables the measurement of the unit-cell parameters with an uncertainty in the range 0.015-0.06%, depending upon the crystal symmetry and the number of reflections measured. The improved technique also facilitates ...
متن کاملUse of a miniature diamond-anvil cell in high-pressure single-crystal neutron Laue diffraction
The first high-pressure neutron diffraction study in a miniature diamond-anvil cell of a single crystal of size typical for X-ray diffraction is reported. This is made possible by modern Laue diffraction using a large solid-angle image-plate detector. An unexpected finding is that even reflections whose diffracted beams pass through the cell body are reliably observed, albeit with some attenuat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Crystallographica Section A Foundations of Crystallography
سال: 1987
ISSN: 0108-7673
DOI: 10.1107/s0108767387078279