In the present study, a successful attempt has been made to develop a simple method for the simultaneous determination of manganese (II) and iron (III) in an industrial effluent using differential pulse polarography (DPP) technique. Quantification of manganese (II) and iron (III) was done in Triethanolamine and KOH as a supporting electrolyte. The polarogram recorded for the industrial effluent...
متن کاملSimultaneous Determination of Iron(III), Iron(II), and Manganese(II) in Environmental Samples by Ion Chromatography
A chromatographic method was developed for simultaneous determination of Fe(III), Fe(II), Mn(II), and other transition metals. A high-performance polymer-coated silica-based cation exchange column was used for the separation of metals from hydrochloric acid-extracted environmental samples. After separation, the metals were mixed with PAR [4-(2-pyridylazo)resorcinol] and passed through a superco...
متن کاملDetermination of citrate as its iron(III) complex by differential pulse polarography.
A method for determining citrate as its complex with iron(II1) by differential pulse polarography is described. The method is sensitive to 5 pg ml-1 of citrate, without any interference from equimolar propan-2-onedicarboxylate and propenetricarboxylate ions and 10% of oxalate and tartrate ions. The limits of error in citrate concentrations determined by the proposed method are better than &2.6y...
متن کاملsimultaneous determination of zinc and lead in blood samples by differential pulse polarography
in present study we determine the zinc and lead levels in human blood samples by differential pulse polarography under optimum experimental conditions (ph=7.5, scan rate=5mv/s and pulse amplitude=50mv) the polarographic reduction peaks of zn and pb were examinedin the -0.72 v and-0.15 respectively. the zinc and lead content can be determined by in comparison with their standard solutions. accor...
متن کاملReverse Differential Pulse Voltammetry and Polarography
In this paper we obtain the analytical solution for the reverse Werential pulse O P ) technique for a slow electronic transfer process, starting fkom expressions obtained previously for the faradaic response to a triple potential pulse. The solutions are valid for the planar approximations of a static mercury drop electrode and of a dropping mercury electrode. An irreversible reduction process ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IOSR Journal of Applied Chemistry
سال: 2012
ISSN: 2278-5736
DOI: 10.9790/5736-0122428