Simultaneous Echo Refocused Magnetization Transfer Imaging
نویسندگان
چکیده
منابع مشابه
Simultaneous Echo Refocused Magnetization Transfer Imaging
Purpose: To increase the efficiency of densely encoded magnetization transfer imaging of the brain, we time-multiplex multiple slices within the same readout using simultaneous echo refocusing FLASH imaging with magnetization transfer (MT) preparation (MT-SER-FLASH). Materials and Methods: Inefficiency in total scan time results from the number of frequency samples needed for sufficient quality...
متن کاملPulsed magnetization transfer spin-echo MR imaging.
Cross relaxation between macromolecular protons and water protons is known to be important in biologic tissue. In magnetic resonance (MR) imaging sequences, selective saturation of the characteristically short T2 macromolecular proton pool can produce contrast called magnetization transfer contrast, based on the cross-relaxation process. Selective saturation can be achieved with continuous wave...
متن کاملMagnetization Transfer Prepared Gradient Echo MRI for CEST Imaging
Chemical exchange saturation transfer (CEST) is an emerging MRI contrast mechanism that is capable of noninvasively imaging dilute CEST agents and local properties such as pH and temperature, augmenting the routine MRI methods. However, the routine CEST MRI includes a long RF saturation pulse followed by fast image readout, which is associated with high specific absorption rate and limited spat...
متن کاملRefocused Turbo Spin Echo for Noncontrast MRA
Introduction There is increasing interest in non-contrast MRA methods because of the risk of NSF in patients with kidney disease [1]. RARE-type sequences are capable of generating contrast between blood and surrounding tissue based on T2 differences, but conventional RARE sequences have a non-zero first moment at the RF pulses and at odd echoes, and are therefore susceptible to flow-related art...
متن کاملQuantitative magnetization transfer ultrashort echo time imaging of the Achilles tendon.
Ultrashort echo time imaging allows the short T(2) Achilles tendon to be directly visualized with MRI. Radiofrequency saturation 1 kHz or less off-resonance has been used previously to improve image contrast. In this study, magnetization transfer was investigated in the Achilles tendon of eight normal volunteers and one patient with psoriatic arthritis. 2D Ultrashort echo time images were acqui...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Open Journal of Medical Imaging
سال: 2014
ISSN: 2164-2788,2164-2796
DOI: 10.4236/ojmi.2014.43021