Simulations of the rf heating rates in a linear quadrupole ion trap
Molecular dynamics simulations of the ion clouds stored in a linear quadrupole rf ion trap are performed at low temperatures s0.1 mK–15 Kd. The introduction of periodic boundary conditions allowed us to study the translationally uniform ion cloud geometry. The time evolution of the kinetic energy of the ion cloud is monitored during the simulation and the increase in the kinetic energy of the c...
متن کاملQuadrupole ion trap mass spectrometry.
A number of other features of ITMS systems that will enhance their ability to analyze biological macromolecules are worth mentioning. As has already been demonstrated for ESI/quadrupole, ESI/magnetic sector, and ESI/FTICR systems, the capability of inducing fragmentation of the ESI-generated multiply charged ions of biological macromolecules in the capillary/skimmer region of the ESI source and...
متن کاملLaser-cooling of Ions and Ion Acceleration in the RF-Quadrupole Ring Trap PALLAS
We report on the commissioning of the table-top RF-Quadrupole storage ring PALLAS , dedicated to the experimental realization of crystalline ion beams. Images of large prolate 24Mg+-ion crystals are presented, operating PALLAS locally as a linear rf-trap and applying laser-cooling, beautifully confirming prior theoretical and experimental work. For few-ion strings, a radial oscillation of the c...
متن کاملObservation of ion Coulomb crystals in a cryogenic linear octupole rf ion trap
K. Okada,* T. Takayanagi, M. Wada, S. Ohtani, and H. A. Schuessler Department of Physics, Sophia University, 7-1 Kioicho, Chiyoda, Tokyo 102-8554, Japan Atomic Physics Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan Institute for Laser Science (ILS), University of Electro-Communications, 1-5-1 Chofugaoka, Chofu, Tokyo 182-8585, Japan Department of Physics, Texas A&M University, C...
متن کاملAn interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system.
A new ion sampling interface for an electrospray ionization 3D ion trap mass spectrometer system is described. The interface uses linear rf quadrupoles as ion guides and ion traps to enhance the performance of the 3D trap. Trapping ions in the linear quadrupoles is demonstrated to improve the duty cycle of the system. Dipolar excitation of ions trapped in a linear quadrupole is used to eject un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review A
سال: 2005
ISSN: 1050-2947,1094-1622
DOI: 10.1103/physreva.71.033414