Simulation Test of a DC Fault Current Limiter for Fault Ride-Through Problem of Low-Voltage DC Distribution
نویسندگان
چکیده
منابع مشابه
Protection Principle for a DC Distribution System with a Resistive Superconductive Fault Current Limiter
A DC distribution system, which is suitable for access to distributed power generation and DC loads, is one of the development directions in power systems. Furthermore, it could greatly improve the energy efficiency and reduce the loss of power transportation. The huge short circuit current is always a great threat to the safety of the components, especially the capacitors and diodes. A resisti...
متن کاملA New Method to Enhance the Low Voltage Ride Through Capability of Doubly Fed Induction Generator Using Resistive Type Superconducting Fault Current Limiter
In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is consid...
متن کاملDC Fault Ride-through Capability and STATCOM Operation of a HVDC Hybrid Voltage Source Converter
HVDC transmission systems are becoming increasingly popular when compared to conventional AC transmission methods. HVDC voltage source converters (VSC) can offer advantages over traditional HVDC current source converter topologies; as such, it is expected that HVDC-VSCs will be further exploited with the growth of HVDC transmission. This paper presents the DC fault ride through capability and n...
متن کاملThe Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System
In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...
متن کاملImprovement of Low Voltage Ride – through Capability of Distributed Generation in a Microgrid Using Superconducting Fault Current Limiter
Although the introduction of distributed generation (DG) in a distribution system improves the power quality of power system, it increases the fault current level reducing voltage at point of common-coupling (PCC). Hence, there is a need of improving fault ride-through (FRT) capability to avoid sudden tripping of DG units from the utility grid during voltage sag in a faulty condition. In this p...