Simulation of Three-Phase Salient Pole Generator under Operating Conditions
نویسندگان
چکیده
منابع مشابه
The Vector Control of Three-Phase Salient Pole Synchronous Machines Supplied by Pulse-Width- Modulated Voltage Source Inverters
In this paper, computer simulation of a three-phase synchronous motor drive is described. This drive/system is supplied with a new type of pulse-width modulated voltage source inverter (PWM VSI) whose amplitude of the first harmonic, compared to a conventional sinusoidal PWM VSI, is increased by about 17% and whose amplitude of higher harmonics is also reduced inversely proportional to their or...
متن کاملThe Vector Control of Three-Phase Salient Pole Synchronous Machines Supplied by Pulse-Width- Modulated Voltage Source Inverters
In this paper, computer simulation of a three-phase synchronous motor drive is described. This drive/system is supplied with a new type of pulse-width modulated voltage source inverter (PWM VSI) whose amplitude of the first harmonic, compared to a conventional sinusoidal PWM VSI, is increased by about 17% and whose amplitude of higher harmonics is also reduced inversely proportional to their or...
متن کاملTime-stepping Finite-element Analysis of Dy- Namic Eccentricity Fault in a Three-phase Salient Pole Synchronous Generator
In this paper, two-dimensional time-stepping finiteelement (TSFE) method is performed for modeling and analyzing of a salient pole synchronous generator with different degree of dynamic eccentricity (DE) fault. TSFE analysis is used to describe the influence of DE fault on the flux distribution within the generator and no-load voltage profiles at low and high field current is obtained for healt...
متن کاملComputer Simulation and Operating Characteristics of a Three{phase Brushless Synchronous Generator
This paper deals with numerical computation and simulation of the operating conditions of a three-phase brushless synchronous generator. A voltage driven nonlinear time-periodic nite element analysis is utilized to compute accurately the magnetic eld distribution and the induced voltage and currents. The computation procedure is brie y addressed followed by the computed results and their compar...
متن کاملAnalysis of Magnetic Flux Linkage Distribution in Salient-Pole Synchronous Generator with Different Kinds of Inter-Turn Winding Faults
A reliable and accurate diagnosis of inter-turn short circuit faults is a challenging problem in the area of fault diagnosis of electrical machines. The purpose of this challenge is to be more efficient in fault detection and to provide a reliable method with low-cost sensors and simple numerical algorithms which not only detect the occurrence of the fault, but also locate its position in the w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Southwest Jiaotong University
سال: 2019
ISSN: 0258-2724
DOI: 10.35741/issn.0258-2724.54.4.12