Simulation of Square Wave Voltammetry of Three Step Redox Reactions on Spherical Electrodes

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Square Wave Voltammetry of Three Step Redox Reactions on Spherical Electrodes

The theory of three step electrode reaction is developed for square wave voltammetry on stationary spherical electrodes. It was assumed that all electroactive species are solution soluble. The dependence of the response on the thermodynamic stability of intermediates, on the electrode radius and the scan direction is investigated for the fast and reversible electrode reactions. The criterion of...

متن کامل

Simulation of square wave voltammetry of three electrode reactions coupled by two reversible chemical reactions

Three fast and reversible electrode reactions that are connected by two reversible chemical reactions that are permanently in the equilibrium are analysed theoretically for square wave voltammetry. The dependence of peak potentials on the dimensionless equilibrium constants of chemical reactions is calculated. The influence of the basic thermodynamic parameters on the square wave voltammetric r...

متن کامل

Redox properties of several bacterial ferredoxins using square wave voltammetry.

The equilibrium reduction potential of the 2[4Fe-4S] ferredoxin (Fd) isolated from four different bacterial strains was determined at a methyl viologen-modified gold electrode using square wave voltammetry. The observed reduction potential at pH 8 for Clostridium thermoaceticum Fd was -385 mV; Clostridium pasteurianum, -393 mV; Clostridium thermosaccharolyticum, -408 mV; and Chromatium vinosum,...

متن کامل

Electroanalytical Determination of 4-Nitrophenol by Square Wave Voltammetry on Diamond Electrodes

O comportamento voltamétrico do 4-nitrofenol foi estudado em meio aquoso sobre o eletrodo de diamante dopado com boro usando a voltametria de onda quadrada. Após a otimização dos parâmetros experimentais, o estudo foi realizado em tampão Britton-Robinson com pH 6,0. Nestas condições foi observado somente um pico de oxidação em torno de 1,0 V vs. Ag/AgCl com transferência de dois elétrons e um p...

متن کامل

Determination of clopidogrel using square wave voltammetry

The determination of clopidogrel, an antiplatelet agent, was performed at a gold electrode in pH 3.7 acetate buffer using cyclic voltammetry (CV) and square wave voltammetry (SWV). Each voltammogram was characterized by the well defined peak at approximately 1.0 V. The current of anodic stripping peak exhibited a linear dependence on the clopidogrel concentration in the range from 317.89 to 935...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Croatica Chemica Acta

سال: 2017

ISSN: 0011-1643,1334-417X

DOI: 10.5562/cca3048